Certified by EPA ENERGY STAR, Delta ELT50-110MH delivers 110 CFM free-air (112.4 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 112 sq ft (8-ft height) or 99 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT50-110MH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 112.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.3 CFM/W (#258/1,145)
- Static Retention
- 102.2% @ 0.25"
- Motor Draw
- 11.8 W (4.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta ELT50-110MH vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta ELT50-110MH (EPA filing PD #4618996) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.4 CFM out of 110 CFM (102.2% retention, 14.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Delta registers 121 certified models, with SKU ELT50-110MH (series: BreezElite) (PD #4618996) certified since 2026-03-25. Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.8 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 103.4 kWh/yr (~$16.54/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
Why does rigid 4 in. diameter ducting protect Delta ELT50-110MH airflow?
Connecting Delta ELT50-110MH through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Delta ELT50-110MH performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta ELT50-110MH lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ELT50-110MH / BreezElite | PD ID 4618996 (Qualified 2026-03-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (112.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Delta ELT50-110MH?
Calculated coverage metrics translate Delta ELT50-110MH airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.3 kWh/yr (~$0.69/yr) | 11.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 103.4 kWh/yr (~$16.54/yr) | 11.8 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Delta ELT50-110MH?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Does Delta ELT50-110MH match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta ELT50-110MH percentage capacity without sending data.
What plumbing or duct constraints rule out Delta ELT50-110MH?
Compare where Delta ELT50-110MH excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 112.4 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Delta ELT50-110MH?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta ELT50-110MH.
Can Delta ELT50-110MH serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta ELT50-110MH supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Delta ELT50-110MH for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ELT50-110MH lacks adequate reserve.
How does Delta ELT50-110MH handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ELT50-110MH yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Delta ELT50-110MH quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Delta ELT50-110MH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Delta ELT50-110MH energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta ELT50-110MH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT50-110MH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta ELT50-110MH?
Delta ELT50-110MH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta ELT50-110MH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT50-110MH's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)