Skip to main content
Grant Estimator

Fantech PB110L10 (44943) Exhaust Fan Specifications

ENERGY STAR PD #2393570 · Bathroom/Utility Room · Qualified 2022-03-04
Verified Specification Summary

Certified by EPA ENERGY STAR, Fantech PB110L10 (44943) delivers 100 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 100 sq ft (8-ft height) or 88 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB110L10 (44943) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.5 CFM/W (#471/1,145)
Static Retention
0.1" test only
Motor Draw
18.2 W (6.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech PB110L10 (44943) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech PB110L10 (44943) (EPA filing PD #2393570) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Fantech's 52-unit lineup, PB110L10 (44943) (series: PB 110 Series) carries PD #2393570 dating to 2022-03-04. Lighting kit: Yes. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Utilitech 7115-01 (100.0 CFM) and ACIQ AES100 (100.0 CFM).

Why does rigid 4 in. diameter ducting protect Fantech PB110L10 (44943) airflow?

Connecting Fantech PB110L10 (44943) through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Fantech PB110L10 (44943) performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech PB110L10 (44943) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series PB110L10 (44943) / PB 110 Series PD ID 2393570 (Qualified 2022-03-04)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (100 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Fantech PB110L10 (44943)?

Calculated coverage metrics translate Fantech PB110L10 (44943) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Fantech PB110L10 (44943)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 100 sq ft1 CFM/sq ft @ 100 CFM
Tall Bath (9-ft Ceiling)Up to 88 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 50 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.6 kWh/yr (~$1.06/yr)18.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2159.4 kWh/yr (~$25.50/yr)18.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Fantech PB110L10 (44943)?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7115-01 100 / 95.4 CFM 1.5 sones 6.5 CFM/W 4 in. diameter
ACIQ AES100 100 / 90.2 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
CFM TF100N 100 / 90.2 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
S&P PCLP100XP 100 / 90.2 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter

Does Fantech PB110L10 (44943) match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech PB110L10 (44943) percentage capacity without sending data.

What plumbing or duct constraints rule out Fantech PB110L10 (44943)?

Compare where Fantech PB110L10 (44943) excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 100 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Fantech PB110L10 (44943)?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech PB110L10 (44943).

Can Fantech PB110L10 (44943) serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Fantech PB110L10 (44943) supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Fantech PB110L10 (44943) for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Fantech PB110L10 (44943) lacks adequate reserve.

How does Fantech PB110L10 (44943) handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Fantech PB110L10 (44943) yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Fantech PB110L10 (44943) quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Fantech PB110L10 (44943) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Fantech PB110L10 (44943) energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Fantech PB110L10 (44943) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB110L10 (44943)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech PB110L10 (44943)?

Fantech PB110L10 (44943) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech PB110L10 (44943)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB110L10 (44943)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories