Rated for 100 CFM open-air (unpublished 0.25 in. w.g. output), Fantech PB110L7 (44942) omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 100 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB110L7 (44942) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.5 CFM/W (#471/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 18.2 W (6.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Fantech PB110L7 (44942) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech PB110L7 (44942) (EPA filing PD #2393568) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Fantech maintains 52 active ENERGY STAR blowers; PB110L7 (44942) (series: PB Series) (PD #2393568) gained qualification on 2022-03-04. Lighting kit: Yes. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Utilitech 7115-01 (100.0 CFM) and ACIQ AES100 (100.0 CFM).
How do flex elbows choke Fantech PB110L7 (44942) at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Fantech PB110L7 (44942) moving full rated CFM.
Does Fantech PB110L7 (44942) meet residential exhaust fan code specs?
Inspect Fantech PB110L7 (44942) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PB110L7 (44942) / PB Series | PD ID 2393568 (Qualified 2022-03-04) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Fantech PB110L7 (44942) airflow output?
Annual electricity figures and room square-footage ceilings below reflect Fantech PB110L7 (44942) tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |
Which competing models share Fantech PB110L7 (44942) airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7115-01 | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| ACIQ AES100 | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| CFM TF100N | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| S&P PCLP100XP | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
How much airflow margin does Fantech PB110L7 (44942) give your bath?
Run a quick local room-volume check for Fantech PB110L7 (44942) by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Fantech PB110L7 (44942)?
Match Fantech PB110L7 (44942) directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 100 sq ft with 8-ft ceilings (88 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Fantech PB110L7 (44942)?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Fantech PB110L7 (44942).
Where does Fantech PB110L7 (44942) sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Fantech PB110L7 (44942) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Fantech PB110L7 (44942) cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Fantech PB110L7 (44942) 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Fantech PB110L7 (44942) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB110L7 (44942)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech PB110L7 (44942)?
Fantech PB110L7 (44942) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech PB110L7 (44942)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB110L7 (44942)'s safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Fantech PB110L7 (44942) ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Fantech PB110L7 (44942) covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Fantech PB110L7 (44942) run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Fantech PB110L7 (44942).
What happens to Fantech PB110L7 (44942) CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Fantech PB110L7 (44942) moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)