Skip to main content
Grant Estimator

Fantech SF50-80-100L (484306) Exhaust Fan Specifications

ENERGY STAR PD #2546668 · Bathroom/Utility Room · Qualified 2023-04-28
Verified Specification Summary

Homeowners specifying Fantech SF50-80-100L (484306) gain 100 CFM at 0.1 in. w.g. (106.5 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, venting bathrooms up to 106 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SF50-80-100L (484306) Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
100 / 106.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.3 CFM/W (#258/1,145)
Static Retention
106.5% @ 0.25"
Motor Draw
10.8 W (3.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech SF50-80-100L (484306) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech SF50-80-100L (484306) (EPA filing PD #2546668) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Fantech SF50-80-100L (484306) (series: bathfan Select Fit) under PD #2546668 (52 models registered, 2023-04-28). Lighting kit: Yes. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

Which exterior damper path suits Fantech SF50-80-100L (484306) best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Fantech SF50-80-100L (484306) housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Fantech SF50-80-100L (484306) acoustic and static metrics stand?

Compare Fantech SF50-80-100L (484306) published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series SF50-80-100L (484306) / bathfan Select Fit PD ID 2546668 (Qualified 2023-04-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Fantech SF50-80-100L (484306) handle taller ceilings or walk-in tub steam?

Evaluate how Fantech SF50-80-100L (484306) scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Fantech SF50-80-100L (484306)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106.5 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.294.6 kWh/yr (~$15.14/yr)10.8 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Fantech SF50-80-100L (484306)?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Is Fantech SF50-80-100L (484306) sized right for your shower or tub room?

Check whether Fantech SF50-80-100L (484306) clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Where should contractors skip Fantech SF50-80-100L (484306) on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantech SF50-80-100L (484306) carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 56 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 106.5 CFM net static output
  • Works well for: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Fantech SF50-80-100L (484306)?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Fantech SF50-80-100L (484306).

What duct and room conditions disqualify Fantech SF50-80-100L (484306)?

Rule out Fantech SF50-80-100L (484306) when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Fantech SF50-80-100L (484306) capacity?

Because static drag at 0.25 in. w.g. lowers Fantech SF50-80-100L (484306) from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Fantech SF50-80-100L (484306) compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Fantech SF50-80-100L (484306) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Fantech SF50-80-100L (484306) consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Fantech SF50-80-100L (484306) draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Fantech SF50-80-100L (484306) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SF50-80-100L (484306)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech SF50-80-100L (484306)?

Fantech SF50-80-100L (484306) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech SF50-80-100L (484306)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SF50-80-100L (484306)'s safe coverage footprint from 50 sq ft to 44 sq ft.

How does Fantech SF50-80-100L (484306) score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Fantech SF50-80-100L (484306) delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories