Fantech SFC50-80-100 (484307) Exhaust Fan Specifications

ENERGY STAR PD #2546753 · Bathroom/Utility Room · Qualified 2023-04-28
Verified Specification Summary

In EPA dataset 8dv7-nngq, Fantech SFC50-80-100 (484307) tests at 100 CFM free discharge (106.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 106 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SFC50-80-100 (484307) Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
100 / 106.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.3 CFM/W (#258/1,145)
Static Retention
106.5% @ 0.25"
Motor Draw
10.8 W (3.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech SFC50-80-100 (484307) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech SFC50-80-100 (484307) (EPA filing PD #2546753) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places SFC50-80-100 (484307) (series: bathfan Select Fit) (PD #2546753) among 52 Fantech entries qualified through 2023-04-28. Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

Why avoid unvented attic termination with Fantech SFC50-80-100 (484307)?

Under ASHRAE 62.2 best practice, Fantech SFC50-80-100 (484307) needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Fantech SFC50-80-100 (484307)?

Before cutting ceiling drywall or sizing attic transitions for Fantech SFC50-80-100 (484307), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series SFC50-80-100 (484307) / bathfan Select Fit PD ID 2546753 (Qualified 2023-04-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Fantech SFC50-80-100 (484307)?

Bathroom ventilation sizing below maps Fantech SFC50-80-100 (484307) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Fantech SFC50-80-100 (484307)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106.5 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.294.6 kWh/yr (~$15.14/yr)10.8 W x 8,760 hrs / 1,000

What peer models sit nearest Fantech SFC50-80-100 (484307) in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech SFC50-80-100 (484307).

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

What percentage of room demand does Fantech SFC50-80-100 (484307) cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech SFC50-80-100 (484307) tested delivery.

Which bath layouts should avoid specifying Fantech SFC50-80-100 (484307)?

Match Fantech SFC50-80-100 (484307) directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 106.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 106 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Fantech SFC50-80-100 (484307)?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech SFC50-80-100 (484307).

What does Fantech SFC50-80-100 (484307) cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Fantech SFC50-80-100 (484307) 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Fantech SFC50-80-100 (484307) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SFC50-80-100 (484307)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech SFC50-80-100 (484307)?

Fantech SFC50-80-100 (484307) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech SFC50-80-100 (484307)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SFC50-80-100 (484307)'s safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Fantech SFC50-80-100 (484307) ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Fantech SFC50-80-100 (484307) covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Fantech SFC50-80-100 (484307) run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Fantech SFC50-80-100 (484307).

What happens to Fantech SFC50-80-100 (484307) CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Fantech SFC50-80-100 (484307) moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Fantech SFC50-80-100 (484307) sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Fantech SFC50-80-100 (484307) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories