Fantech SFC50-80-100HO (484309) Exhaust Fan Specifications

ENERGY STAR PD #2546750 · Bathroom/Utility Room · Qualified 2023-04-28
Verified Specification Summary

Tested under HVI protocols, the Fantech SFC50-80-100HO (484309) exhaust unit achieves 100 CFM at 0.1 in. w.g. (106.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, covering standard baths up to 106 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SFC50-80-100HO (484309) Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
100 / 106.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.3 CFM/W (#258/1,145)
Static Retention
106.5% @ 0.25"
Motor Draw
10.8 W (3.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech SFC50-80-100HO (484309) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech SFC50-80-100HO (484309) (EPA filing PD #2546750) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU SFC50-80-100HO (484309) (series: bathfan Select Fit) (PD #2546750) certified since 2023-04-28. Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

What attic duct routing preserves Fantech SFC50-80-100HO (484309) CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech SFC50-80-100HO (484309), preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Fantech SFC50-80-100HO (484309) measure up on airflow and noise ratings?

Each row below breaks down Fantech SFC50-80-100HO (484309) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series SFC50-80-100HO (484309) / bathfan Select Fit PD ID 2546750 (Qualified 2023-04-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Fantech SFC50-80-100HO (484309) CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Fantech SFC50-80-100HO (484309)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106.5 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.294.6 kWh/yr (~$15.14/yr)10.8 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Fantech SFC50-80-100HO (484309)?

Compare Fantech SFC50-80-100HO (484309) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Can you size Fantech SFC50-80-100HO (484309) for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech SFC50-80-100HO (484309) verified capacity.

When does Fantech SFC50-80-100HO (484309) fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech SFC50-80-100HO (484309).

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 106.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 106 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Fantech SFC50-80-100HO (484309)?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech SFC50-80-100HO (484309).

Which bathroom layouts should pick a larger blower than Fantech SFC50-80-100HO (484309)?

Do not force Fantech SFC50-80-100HO (484309) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Fantech SFC50-80-100HO (484309) retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Fantech SFC50-80-100HO (484309) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Fantech SFC50-80-100HO (484309) disturb adjacent bedrooms during night use?

Acoustic measurement places Fantech SFC50-80-100HO (484309) at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Fantech SFC50-80-100HO (484309) continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Fantech SFC50-80-100HO (484309) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Fantech SFC50-80-100HO (484309) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SFC50-80-100HO (484309)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech SFC50-80-100HO (484309)?

Fantech SFC50-80-100HO (484309) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech SFC50-80-100HO (484309)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SFC50-80-100HO (484309)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Is Fantech SFC50-80-100HO (484309) code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech SFC50-80-100HO (484309) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.