The Fantech SC50-80-110 (484313) (bathfan Select) moves 110 CFM at 0.1 in. w.g. (114.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 10.7 CFM/W efficacy, sizing bathrooms up to 114 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SC50-80-110 (484313) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 114.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.7 CFM/W (#144/1,145)
- Static Retention
- 104.3% @ 0.25"
- Motor Draw
- 10.3 W (3.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Fantech SC50-80-110 (484313) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech SC50-80-110 (484313) (EPA filing PD #2507832) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.7 CFM out of 110 CFM (104.3% retention, 16.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Fantech maintains 52 active ENERGY STAR blowers; SC50-80-110 (484313) (series: bathfan Select) (PD #2507832) gained qualification on 2023-05-19. Lighting kit: No. At 10.7 CFM/W (#144 of 1,145, top 13.2% of 1,145 rated models, more efficient than 86.8% of rated models, 6.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.3 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 90.2 kWh/yr (~$14.43/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
How does duct geometry alter Fantech SC50-80-110 (484313) static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Fantech SC50-80-110 (484313)?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Fantech SC50-80-110 (484313) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SC50-80-110 (484313) / bathfan Select | PD ID 2507832 (Qualified 2023-05-19) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (114.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Fantech SC50-80-110 (484313) ventilate safely?
Sizing outputs below convert Fantech SC50-80-110 (484313) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 90.2 kWh/yr (~$14.43/yr) | 10.3 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Fantech SC50-80-110 (484313) closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
Will Fantech SC50-80-110 (484313) clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Fantech SC50-80-110 (484313) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Fantech SC50-80-110 (484313) suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech SC50-80-110 (484313) for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 64 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 114 sq ft with 8-ft ceilings (101 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Fantech SC50-80-110 (484313)?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Fantech SC50-80-110 (484313).
Does duct resistance cut Fantech SC50-80-110 (484313) airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech SC50-80-110 (484313) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Fantech SC50-80-110 (484313) occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech SC50-80-110 (484313) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Fantech SC50-80-110 (484313) add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Fantech SC50-80-110 (484313) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Fantech SC50-80-110 (484313) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SC50-80-110 (484313)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech SC50-80-110 (484313)?
Fantech SC50-80-110 (484313) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech SC50-80-110 (484313)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SC50-80-110 (484313)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Fantech SC50-80-110 (484313) pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech SC50-80-110 (484313) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Fantech SC50-80-110 (484313) in a bathroom remodel?
Avoid specifying Fantech SC50-80-110 (484313) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)