Fantech SC50-80-110L (484314) Exhaust Fan Specifications

ENERGY STAR PD #2507881 · Bathroom/Utility Room · Qualified 2023-05-19
Verified Specification Summary

In EPA dataset 8dv7-nngq, Fantech SC50-80-110L (484314) tests at 110 CFM free discharge (114.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 114 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SC50-80-110L (484314) Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
110 / 114.7 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
10.7 CFM/W (#144/1,145)
Static Retention
104.3% @ 0.25"
Motor Draw
10.3 W (3.8 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech SC50-80-110L (484314) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech SC50-80-110L (484314) (EPA filing PD #2507881) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.7 CFM out of 110 CFM (104.3% retention, 16.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2507881 verifies SC50-80-110L (484314) (series: bathfan Select) under Fantech (52 listed models, qualified 2023-05-19). Lighting kit: Yes. At 10.7 CFM/W (#144 of 1,145, top 13.2% of 1,145 rated models, more efficient than 86.8% of rated models, 6.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.3 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 90.2 kWh/yr (~$14.43/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

Why avoid unvented attic termination with Fantech SC50-80-110L (484314)?

Under ASHRAE 62.2 best practice, Fantech SC50-80-110L (484314) needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Fantech SC50-80-110L (484314)?

Before cutting ceiling drywall or sizing attic transitions for Fantech SC50-80-110L (484314), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series SC50-80-110L (484314) / bathfan Select PD ID 2507881 (Qualified 2023-05-19)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (114.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Fantech SC50-80-110L (484314)?

Bathroom ventilation sizing below maps Fantech SC50-80-110L (484314) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Fantech SC50-80-110L (484314)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 114 sq ft1 CFM/sq ft @ 114.7 CFM
Tall Bath (9-ft Ceiling)Up to 101 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 64 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.8 kWh/yr (~$0.61/yr)10.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.290.2 kWh/yr (~$14.43/yr)10.3 W x 8,760 hrs / 1,000

What peer models sit nearest Fantech SC50-80-110L (484314) in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech SC50-80-110L (484314).

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter

What percentage of room demand does Fantech SC50-80-110L (484314) cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech SC50-80-110L (484314) tested delivery.

Does Fantech SC50-80-110L (484314) suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech SC50-80-110L (484314) for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 114.7 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 114 sq ft
  • Best application: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Fantech SC50-80-110L (484314)?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech SC50-80-110L (484314).

Does duct resistance cut Fantech SC50-80-110L (484314) airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech SC50-80-110L (484314) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Fantech SC50-80-110L (484314) occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech SC50-80-110L (484314) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Fantech SC50-80-110L (484314) add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Fantech SC50-80-110L (484314) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Fantech SC50-80-110L (484314) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SC50-80-110L (484314)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech SC50-80-110L (484314)?

Fantech SC50-80-110L (484314) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech SC50-80-110L (484314)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SC50-80-110L (484314)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Does Fantech SC50-80-110L (484314) pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech SC50-80-110L (484314) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Fantech SC50-80-110L (484314) in a bathroom remodel?

Avoid specifying Fantech SC50-80-110L (484314) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)