Skip to main content
Grant Estimator

Greenheck SP-LP0511HL Exhaust Fan Specifications

ENERGY STAR PD #4517842 · Bathroom/Utility Room · Qualified 2025-12-05
Verified Specification Summary

Certified by EPA ENERGY STAR, Greenheck SP-LP0511HL delivers 110 CFM free-air (117.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 117 sq ft (8-ft height) or 104 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-LP0511HL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 117.7 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.3 CFM/W (#321/1,145)
Static Retention
107.0% @ 0.25"
Motor Draw
13.3 W (4.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-LP0511HL vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-LP0511HL (EPA filing PD #4517842) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 117.7 CFM out of 110 CFM (107.0% retention, 19.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Greenheck registers 31 certified models, with SKU SP-LP0511HL (series: Model SP Ceiling Fan, Direct Drive) (PD #4517842) certified since 2025-12-05. Lighting kit: Yes. At 8.3 CFM/W (#321 of 1,145, top 28.7% of 1,145 rated models, more efficient than 71.3% of rated models, 3.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.3 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 116.5 kWh/yr (~$18.64/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Delta GBR100LED-DECOR (100.0 CFM).

Why does rigid 4 in. diameter ducting protect Greenheck SP-LP0511HL airflow?

Connecting Greenheck SP-LP0511HL through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Greenheck SP-LP0511HL performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck SP-LP0511HL lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-LP0511HL / Model SP Ceiling Fan, Direct Drive PD ID 4517842 (Qualified 2025-12-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (117.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Greenheck SP-LP0511HL?

Calculated coverage metrics translate Greenheck SP-LP0511HL airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Greenheck SP-LP0511HL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 117 sq ft1 CFM/sq ft @ 117.7 CFM
Tall Bath (9-ft Ceiling)Up to 104 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 67 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.9 kWh/yr (~$0.78/yr)13.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2116.5 kWh/yr (~$18.64/yr)13.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Greenheck SP-LP0511HL?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Greenheck SP-LP0511HL match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck SP-LP0511HL percentage capacity without sending data.

Where should contractors skip Greenheck SP-LP0511HL on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Greenheck SP-LP0511HL carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 67 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 117.7 CFM net static output
  • Works well for: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Greenheck SP-LP0511HL?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck SP-LP0511HL.

What duct and room conditions disqualify Greenheck SP-LP0511HL?

Rule out Greenheck SP-LP0511HL when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Greenheck SP-LP0511HL capacity?

Because static drag at 0.25 in. w.g. lowers Greenheck SP-LP0511HL from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Greenheck SP-LP0511HL compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Greenheck SP-LP0511HL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Greenheck SP-LP0511HL consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Greenheck SP-LP0511HL draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Greenheck SP-LP0511HL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-LP0511HL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-LP0511HL?

Greenheck SP-LP0511HL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-LP0511HL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-LP0511HL's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Greenheck SP-LP0511HL score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-LP0511HL delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories