Rated for 110 CFM open-air (94.2 CFM at 0.25 in. w.g.), HomeWerks Worldwide 7141-110-G4 registers #522 of 607 in quietness (2.0 sones) and delivers 4.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 94 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7141-110-G4 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 94.2 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 85.6% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7141-110-G4 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.2 CFM out of 110 CFM (85.6% retention, 2.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside HomeWerks Worldwide's 31-unit lineup, 7141-110-G4 (series: 7141-110-G4) carries PD #2400224 dating to 2022-08-12. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Air King E80S (110.0 CFM) and Air King E80SH (110.0 CFM).
How does HomeWerks Worldwide 7141-110-G4 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against HomeWerks Worldwide 7141-110-G4 (2.0 sones).
How do flex elbows choke HomeWerks Worldwide 7141-110-G4 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps HomeWerks Worldwide 7141-110-G4 moving full rated CFM.
Does HomeWerks Worldwide 7141-110-G4 meet residential exhaust fan code specs?
Inspect HomeWerks Worldwide 7141-110-G4 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7141-110-G4 / 7141-110-G4 | PD ID 2400224 (Qualified 2022-08-12) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (94.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match HomeWerks Worldwide 7141-110-G4 airflow output?
Annual electricity figures and room square-footage ceilings below reflect HomeWerks Worldwide 7141-110-G4 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
Which competing models share HomeWerks Worldwide 7141-110-G4 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King E80S | 110 / 115.9 CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| Air King E80SH | 110 / 115.9 CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| Win Air BPT14-24A-2 | 110 / 100.4 CFM | Unpublished | 4.5 CFM/W | 4 in. diameter |
| Commercial Electric BF1107 | 110 / 88.6 CFM | Unpublished | 4.3 CFM/W | 4 in. diameter |
| Akicon AK13110N4-B | 110 / 87.4 CFM | 2.0 sones (Same) | 4.2 CFM/W | 4 in. diameter |
How much airflow margin does HomeWerks Worldwide 7141-110-G4 give your bath?
Run a quick local room-volume check for HomeWerks Worldwide 7141-110-G4 by entering square footage and ceiling height to spot under-vented steam risks early.
What plumbing or duct constraints rule out HomeWerks Worldwide 7141-110-G4?
Compare where HomeWerks Worldwide 7141-110-G4 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 44 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 94 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about HomeWerks Worldwide 7141-110-G4?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to HomeWerks Worldwide 7141-110-G4.
Why might a contractor swap HomeWerks Worldwide 7141-110-G4 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, HomeWerks Worldwide 7141-110-G4 lacks adequate reserve.
How does HomeWerks Worldwide 7141-110-G4 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., HomeWerks Worldwide 7141-110-G4 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is HomeWerks Worldwide 7141-110-G4 quiet enough for a primary bedroom bathroom?
At 2.0 sones, HomeWerks Worldwide 7141-110-G4 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is HomeWerks Worldwide 7141-110-G4 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can HomeWerks Worldwide 7141-110-G4 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7141-110-G4's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7141-110-G4?
HomeWerks Worldwide 7141-110-G4 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7141-110-G4's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7141-110-G4's safe coverage footprint from 50 sq ft to 44 sq ft.
Can HomeWerks Worldwide 7141-110-G4 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: HomeWerks Worldwide 7141-110-G4 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)