In EPA dataset 8dv7-nngq, Air King E80S tests at 110 CFM free discharge (115.9 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 115 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King E80S Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 115.9 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 105.4% @ 0.25"
- Motor Draw
- 24.4 W (8.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Air King E80S vs. 1,145-Model ENERGY STAR Benchmarks show?
Air King E80S (EPA filing PD #2254288) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 115.9 CFM out of 110 CFM (105.4% retention, 17.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places E80S (series: N/A) (PD #2254288) among 62 Air King entries qualified through 2015-12-01. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Tech Drive FA-BF-04-L(BL) (110.0 CFM) and Tech Drive FA-BF-04-L(BN) (110.0 CFM).
Why avoid unvented attic termination with Air King E80S?
Under ASHRAE 62.2 best practice, Air King E80S needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Air King E80S?
Before cutting ceiling drywall or sizing attic transitions for Air King E80S, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | E80S / N/A | PD ID 2254288 (Qualified 2015-12-01) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (115.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Air King E80S?
Bathroom ventilation sizing below maps Air King E80S motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 115 sq ft | 1 CFM/sq ft @ 115.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 103 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 65 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |
What peer models sit nearest Air King E80S in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King E80S.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive FA-BF-04-L(BL) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(BN) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(WH) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT14-24OD-H | 110 / 98.1 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
What percentage of room demand does Air King E80S cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King E80S tested delivery.
Which bath layouts should avoid specifying Air King E80S?
Match Air King E80S directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 115.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around ENERGY STAR sones up to 115 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Air King E80S?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King E80S.
Where does Air King E80S run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King E80S.
What happens to Air King E80S CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Air King E80S moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Air King E80S sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Air King E80S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Air King E80S cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Air King E80S 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Air King E80S pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King E80S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King E80S?
Air King E80S features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King E80S's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King E80S's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Air King E80S ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King E80S covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)