Certified by EPA ENERGY STAR, HomeWerks Worldwide 7148-110-G4 delivers 110 CFM free-air (89.5 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 4.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 89 sq ft (8-ft height) or 79 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7148-110-G4 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 89.5 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 4.1 CFM/W (#821/1,145)
- Static Retention
- 81.4% @ 0.25"
- Motor Draw
- 26.8 W (9.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7148-110-G4 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89.5 CFM at 0.25 in. w.g. (81.4% retention, 6.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
HomeWerks Worldwide maintains 31 active ENERGY STAR blowers; 7148-110-G4 (series: 7148-110-G4) (PD #4610276) gained qualification on 2026-03-25. Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include DewStop - Breeze Easy FL300-2W (110.0 CFM) and RAB CEP10S (110.0 CFM).
How noisy is HomeWerks Worldwide 7148-110-G4 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while HomeWerks Worldwide 7148-110-G4 measures 2.0 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect HomeWerks Worldwide 7148-110-G4 airflow?
Connecting HomeWerks Worldwide 7148-110-G4 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify HomeWerks Worldwide 7148-110-G4 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for HomeWerks Worldwide 7148-110-G4 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7148-110-G4 / 7148-110-G4 | PD ID 4610276 (Qualified 2026-03-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (89.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit HomeWerks Worldwide 7148-110-G4?
Calculated coverage metrics translate HomeWerks Worldwide 7148-110-G4 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.8 kWh/yr (~$1.57/yr) | 26.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 234.8 kWh/yr (~$37.57/yr) | 26.8 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to HomeWerks Worldwide 7148-110-G4?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| DewStop - Breeze Easy FL300-2W | 110 / 89.7 CFM | Unpublished | 4.1 CFM/W | 4 in. diameter |
| RAB CEP10S | 110 / 100.8 CFM | Unpublished | 4.1 CFM/W | 4 in. diameter |
| RAB CEP10SNL | 110 / 100.8 CFM | Unpublished | 4.1 CFM/W | 4 in. diameter |
| Commercial Electric BF1109 | 110 / 93.3 CFM | Unpublished | 4.0 CFM/W | 4 in. diameter |
| Commercial Electric BF1110 | 110 / 93.3 CFM | Unpublished | 4.0 CFM/W | 4 in. diameter |
Does HomeWerks Worldwide 7148-110-G4 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check HomeWerks Worldwide 7148-110-G4 percentage capacity without sending data.
Does HomeWerks Worldwide 7148-110-G4 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying HomeWerks Worldwide 7148-110-G4 for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 39 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 89.5 CFM net static output
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for HomeWerks Worldwide 7148-110-G4?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around HomeWerks Worldwide 7148-110-G4.
How many kWh per year does HomeWerks Worldwide 7148-110-G4 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, HomeWerks Worldwide 7148-110-G4 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can HomeWerks Worldwide 7148-110-G4 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7148-110-G4's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7148-110-G4?
HomeWerks Worldwide 7148-110-G4 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7148-110-G4's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7148-110-G4's safe coverage footprint from 50 sq ft to 44 sq ft.
Does HomeWerks Worldwide 7148-110-G4 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7148-110-G4 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install HomeWerks Worldwide 7148-110-G4 in a bathroom remodel?
Avoid specifying HomeWerks Worldwide 7148-110-G4 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut HomeWerks Worldwide 7148-110-G4 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, HomeWerks Worldwide 7148-110-G4 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does HomeWerks Worldwide 7148-110-G4 occupy in EPA filings?
With 2.0 sones at 0.1 in. w.g., HomeWerks Worldwide 7148-110-G4 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)