Tested under HVI protocols, the Win Air BPT14-24A-2 exhaust unit achieves 110 CFM at 0.1 in. w.g. (100.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy, covering standard baths up to 100 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Win Air BPT14-24A-2 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 100.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 91.3% @ 0.25"
- Motor Draw
- 24.4 W (8.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Win Air BPT14-24A-2 vs. 1,145-Model ENERGY STAR Benchmarks show?
Win Air BPT14-24A-2 (EPA filing PD #3798578) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.4 CFM out of 110 CFM (91.3% retention, 3.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places BPT14-24A-2 (series: BPT) (PD #3798578) among 3 Win Air entries qualified through 2024-11-08. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Tech Drive FA-BF-04-L(BL) (110.0 CFM) and Tech Drive FA-BF-04-L(BN) (110.0 CFM).
What attic duct routing preserves Win Air BPT14-24A-2 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Win Air BPT14-24A-2, preventing premature peeling paint and mold growth.
How does Win Air BPT14-24A-2 measure up on airflow and noise ratings?
Each row below breaks down Win Air BPT14-24A-2 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Win Air (3 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT14-24A-2 / BPT | PD ID 3798578 (Qualified 2024-11-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Win Air BPT14-24A-2 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Win Air BPT14-24A-2?
Compare Win Air BPT14-24A-2 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive FA-BF-04-L(BL) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(BN) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(WH) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT14-24OD-H | 110 / 98.1 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
Can you size Win Air BPT14-24A-2 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Win Air BPT14-24A-2 verified capacity.
When does Win Air BPT14-24A-2 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Win Air BPT14-24A-2.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 100.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 100 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Win Air BPT14-24A-2?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Win Air BPT14-24A-2.
Will Win Air BPT14-24A-2 disturb adjacent bedrooms during night use?
Acoustic measurement places Win Air BPT14-24A-2 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Win Air BPT14-24A-2 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Win Air BPT14-24A-2 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Win Air BPT14-24A-2 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Win Air BPT14-24A-2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Win Air BPT14-24A-2?
Win Air BPT14-24A-2 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Win Air BPT14-24A-2's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Win Air BPT14-24A-2's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Win Air BPT14-24A-2 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Win Air BPT14-24A-2 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Win Air BPT14-24A-2?
Do not force Win Air BPT14-24A-2 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Win Air BPT14-24A-2 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Win Air BPT14-24A-2 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)