Skip to main content
Grant Estimator

KOHLER 34456 Exhaust Fan Specifications

ENERGY STAR PD #4439607 · Bathroom/Utility Room · Qualified 2025-06-20
Verified Specification Summary

Rated for 150 CFM open-air (126 CFM at 0.25 in. w.g.), KOHLER 34456 omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 126 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34456 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 126 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
84.0% @ 0.25"
Motor Draw
34.1 W (12.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KOHLER 34456 vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER 34456 (EPA filing PD #4439607) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 126 CFM at 0.25 in. w.g. (84.0% retention, 3.7 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4439607 verifies 34456 (series: ATMO) under KOHLER (32 listed models, qualified 2025-06-20). Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 34.1 watts, about 12.4 kWh/yr (~$1.98/yr at $0.16/kWh) for 1 hr/day shower timers or 298.7 kWh/yr (~$47.79/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

How do flex elbows choke KOHLER 34456 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps KOHLER 34456 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does KOHLER 34456 meet residential exhaust fan code specs?

Inspect KOHLER 34456 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KOHLER (32 models) ENERGY STAR Certified Partner
Model Number & Series 34456 / ATMO PD ID 4439607 (Qualified 2025-06-20)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (126 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match KOHLER 34456 airflow output?

Annual electricity figures and room square-footage ceilings below reflect KOHLER 34456 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for KOHLER 34456
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 126 sq ft1 CFM/sq ft @ 126 CFM
Tall Bath (9-ft Ceiling)Up to 112 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 76 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.4 kWh/yr (~$1.98/yr)34.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2298.7 kWh/yr (~$47.79/yr)34.1 W x 8,760 hrs / 1,000

Which competing models share KOHLER 34456 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter

How much airflow margin does KOHLER 34456 give your bath?

Run a quick local room-volume check for KOHLER 34456 by entering square footage and ceiling height to spot under-vented steam risks early.

What plumbing or duct constraints rule out KOHLER 34456?

Compare where KOHLER 34456 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 76 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 126 sq ft with 8-ft ceilings (112 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about KOHLER 34456?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to KOHLER 34456.

Is KOHLER 34456 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can KOHLER 34456 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34456's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KOHLER 34456?

KOHLER 34456 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KOHLER 34456's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34456's safe coverage footprint from 50 sq ft to 44 sq ft.

Can KOHLER 34456 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: KOHLER 34456 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap KOHLER 34456 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, KOHLER 34456 lacks adequate reserve.

How does KOHLER 34456 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., KOHLER 34456 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is KOHLER 34456 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, KOHLER 34456 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories