Certified by EPA ENERGY STAR, KOHLER 34457-NA delivers 150 CFM free-air (125.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 125 sq ft (8-ft height) or 111 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34457-NA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 125.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 83.4% @ 0.25"
- Motor Draw
- 33.3 W (12.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does KOHLER 34457-NA vs. 1,145-Model ENERGY STAR Benchmarks show?
KOHLER 34457-NA (EPA filing PD #4528855) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 125.1 CFM at 0.25 in. w.g. (83.4% retention, 4.3 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #4528855 verifies 34457-NA (series: 34457) under KOHLER (32 listed models, qualified 2026-01-28). Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).
Why does rigid 6 in. diameter ducting protect KOHLER 34457-NA airflow?
Connecting KOHLER 34457-NA through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify KOHLER 34457-NA performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for KOHLER 34457-NA lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | KOHLER (32 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 34457-NA / 34457 | PD ID 4528855 (Qualified 2026-01-28) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (125.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit KOHLER 34457-NA?
Calculated coverage metrics translate KOHLER 34457-NA airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 125 sq ft | 1 CFM/sq ft @ 125.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 111 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 75 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to KOHLER 34457-NA?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
Does KOHLER 34457-NA match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check KOHLER 34457-NA percentage capacity without sending data.
Where should contractors skip KOHLER 34457-NA on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KOHLER 34457-NA carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 75 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 125.1 CFM net static output
- Works well for: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for KOHLER 34457-NA?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around KOHLER 34457-NA.
How much power does KOHLER 34457-NA consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, KOHLER 34457-NA draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can KOHLER 34457-NA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34457-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing KOHLER 34457-NA?
KOHLER 34457-NA features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change KOHLER 34457-NA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34457-NA's safe coverage footprint from 50 sq ft to 44 sq ft.
How does KOHLER 34457-NA score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34457-NA delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify KOHLER 34457-NA?
Rule out KOHLER 34457-NA when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke KOHLER 34457-NA capacity?
Because static drag at 0.25 in. w.g. lowers KOHLER 34457-NA from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is KOHLER 34457-NA compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, KOHLER 34457-NA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)