Loren Cook Company GC-128 Exhaust Fan Specifications

ENERGY STAR PD #2250172 · Bathroom/Utility Room · Qualified 2014-11-27
Verified Specification Summary

The Loren Cook Company GC-128 (Gemini, Model GC, 100 Series Ceiling and Wall Blowers) moves 82 CFM at 0.1 in. w.g. (63.2 CFM at 0.25 in. w.g.), registers #239 of 607 in quietness (0.9 sones), and delivers 2.9 CFM/W efficacy, sizing bathrooms up to 63 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Loren Cook Company GC-128 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
82 / 63.2 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
2.9 CFM/W (#1,132/1,145)
Static Retention
77.1% @ 0.25"
Motor Draw
28.3 W (10.3 kWh/yr)
Duct & Tier
5.94 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Loren Cook Company GC-128 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 82 CFM open-air to 63.2 CFM at 0.25 in. w.g. (77.1% retention, 10.6 pts lower retention than the 87.7% median), making smooth 5.94 in. diameter rigid metal runs critical. Keep 5.94 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Loren Cook Company registers 5 certified models, with SKU GC-128 (series: Gemini, Model GC, 100 Series Ceiling and Wall Blowers) (PD #2250172) certified since 2014-11-27. Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.3 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.9 kWh/yr (~$39.66/yr) continuously. Closest competing matches include Broan AER80LMB (80.0 CFM) and Nutone AER80LWH (80.0 CFM).

Where does Loren Cook Company GC-128 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.9 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

How does duct geometry alter Loren Cook Company GC-128 static pressure?

Smooth 5.94 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Loren Cook Company GC-128?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Loren Cook Company GC-128 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Loren Cook Company (5 models) ENERGY STAR Certified Partner
Model Number & Series GC-128 / Gemini, Model GC, 100 Series Ceiling and Wall Blowers PD ID 2250172 (Qualified 2014-11-27)
Duct Connection 5.94 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (63.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Loren Cook Company GC-128 ventilate safely?

Sizing outputs below convert Loren Cook Company GC-128 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Loren Cook Company GC-128
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 63 sq ft1 CFM/sq ft @ 63.2 CFM
Tall Bath (9-ft Ceiling)Up to 56 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.3 kWh/yr (~$1.65/yr)28.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2247.9 kWh/yr (~$39.66/yr)28.3 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Loren Cook Company GC-128 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan AER80LMB 80 / 59.4 CFM 0.8 sones (-0.10) 3.5 CFM/W 4 in. diameter
Nutone AER80LWH 80 / 59.4 CFM 0.8 sones (-0.10) 3.5 CFM/W 4 in. diameter
Nutone AERN80LWH 80 / 59.4 CFM 0.8 sones (-0.10) 3.5 CFM/W 4 in. diameter
ACIQ AP80 80 / 71.6 CFM 1.0 sones (+0.10) 3.6 CFM/W 4 in. diameter
Canarm CP80 80 / 71.6 CFM 1.0 sones (+0.10) 3.6 CFM/W 4 in. diameter

Will Loren Cook Company GC-128 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Loren Cook Company GC-128 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Loren Cook Company GC-128 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Loren Cook Company GC-128.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 63 sq ft with 8-ft ceilings (56 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 5.94 in. diameter

What key rules and numbers govern Loren Cook Company GC-128?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Loren Cook Company GC-128.

Is Loren Cook Company GC-128 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Loren Cook Company GC-128 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Loren Cook Company GC-128?

Do not force Loren Cook Company GC-128 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Loren Cook Company GC-128 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Loren Cook Company GC-128 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 5.94 in. diameter metal duct transitions.

Will Loren Cook Company GC-128 disturb adjacent bedrooms during night use?

Acoustic measurement places Loren Cook Company GC-128 at 0.9 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Loren Cook Company GC-128 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Loren Cook Company GC-128 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Loren Cook Company GC-128 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Loren Cook Company GC-128's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Loren Cook Company GC-128?

Loren Cook Company GC-128 features a 5.94 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Loren Cook Company GC-128's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Loren Cook Company GC-128's safe coverage footprint from 50 sq ft to 44 sq ft.