Skip to main content
Grant Estimator

Ortech ODD-110HS Exhaust Fan Specifications

ENERGY STAR PD #4439147 · Bathroom/Utility Room · Qualified 2025-06-20
Verified Specification Summary

Certified by EPA ENERGY STAR, Ortech ODD-110HS delivers 113 CFM free-air (97.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 97 sq ft (8-ft height) or 86 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-110HS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
113 / 97.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.8 CFM/W (#90/1,145)
Static Retention
86.3% @ 0.25"
Motor Draw
9.6 W (3.5 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODD-110HS vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech ODD-110HS (EPA filing PD #4439147) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.5 CFM out of 113 CFM (86.3% retention, 1.4 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Ortech maintains 27 active ENERGY STAR blowers; ODD-110HS (series: ODD-110HS) (PD #4439147) gained qualification on 2025-06-20. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.6 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 84.1 kWh/yr (~$13.46/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

Why does rigid 4 in. diameter ducting protect Ortech ODD-110HS airflow?

Connecting Ortech ODD-110HS through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Ortech ODD-110HS performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODD-110HS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODD-110HS / ODD-110HS PD ID 4439147 (Qualified 2025-06-20)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (97.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Ortech ODD-110HS?

Calculated coverage metrics translate Ortech ODD-110HS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODD-110HS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 97 sq ft1 CFM/sq ft @ 97.5 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 47 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.5 kWh/yr (~$0.56/yr)9.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.284.1 kWh/yr (~$13.46/yr)9.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Ortech ODD-110HS?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter

Does Ortech ODD-110HS match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODD-110HS percentage capacity without sending data.

Which bath layouts should avoid specifying Ortech ODD-110HS?

Match Ortech ODD-110HS directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 47 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 97.5 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Ortech ODD-110HS?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODD-110HS.

Where does Ortech ODD-110HS run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Ortech ODD-110HS.

What happens to Ortech ODD-110HS CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Ortech ODD-110HS moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Ortech ODD-110HS sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Ortech ODD-110HS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Ortech ODD-110HS cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Ortech ODD-110HS 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Ortech ODD-110HS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-110HS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODD-110HS?

Ortech ODD-110HS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODD-110HS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-110HS's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Ortech ODD-110HS ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Ortech ODD-110HS covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories