Rated for 120 CFM open-air (unpublished 0.25 in. w.g. output), Systemair K 5 (40404) omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 120 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Systemair K 5 (40404) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 120 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.0 CFM/W (#420/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 17.1 W (6.2 kWh/yr)
- Duct & Tier
- 5 in. diameter · Most Eff.

What does Systemair K 5 (40404) vs. 1,145-Model ENERGY STAR Benchmarks show?
Systemair K 5 (40404) (EPA filing PD #4577053) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4577053 verifies K 5 (40404) (series: K Series) under Systemair (1 listed model, qualified 2026-03-25). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.1 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 149.8 kWh/yr (~$23.97/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
How do flex elbows choke Systemair K 5 (40404) at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 5 in. diameter metal pipe keeps Systemair K 5 (40404) moving full rated CFM.
Does Systemair K 5 (40404) meet residential exhaust fan code specs?
Inspect Systemair K 5 (40404) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Systemair (1 model) | ENERGY STAR Certified Partner |
| Model Number & Series | K 5 (40404) / K Series | PD ID 4577053 (Qualified 2026-03-25) |
| Duct Connection | 5 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Systemair K 5 (40404) airflow output?
Annual electricity figures and room square-footage ceilings below reflect Systemair K 5 (40404) tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 149.8 kWh/yr (~$23.97/yr) | 17.1 W x 8,760 hrs / 1,000 |
Which competing models share Systemair K 5 (40404) airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TG-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
How much airflow margin does Systemair K 5 (40404) give your bath?
Run a quick local room-volume check for Systemair K 5 (40404) by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Systemair K 5 (40404) in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Systemair K 5 (40404) for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 5 in. diameter
What should homeowners verify first about Systemair K 5 (40404)?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Systemair K 5 (40404).
What electrical efficiency and runtime kWh define Systemair K 5 (40404)?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Systemair K 5 (40404) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Systemair K 5 (40404)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Systemair K 5 (40404)?
Systemair K 5 (40404) features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Systemair K 5 (40404)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Systemair K 5 (40404)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Systemair K 5 (40404) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Systemair K 5 (40404) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Systemair K 5 (40404) undersized or poorly matched for a bath renovation?
Skip Systemair K 5 (40404) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Systemair K 5 (40404) CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Systemair K 5 (40404) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 5 in. diameter duct runs vital.
How does Systemair K 5 (40404) sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Systemair K 5 (40404) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)