Certified by EPA ENERGY STAR, Fantech FGC 5 (40421) delivers 120 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 120 sq ft (8-ft height) or 106 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FGC 5 (40421) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 120 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.0 CFM/W (#420/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 17.1 W (6.2 kWh/yr)
- Duct & Tier
- 5 in. diameter · Most Eff.

What does Fantech FGC 5 (40421) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech FGC 5 (40421) (EPA filing PD #2407422) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2407422 verifies FGC 5 (40421) (series: FG) under Fantech (52 listed models, qualified 2023-01-27). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.1 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 149.8 kWh/yr (~$23.97/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
Why does rigid 5 in. diameter ducting protect Fantech FGC 5 (40421) airflow?
Connecting Fantech FGC 5 (40421) through rigid 5 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Fantech FGC 5 (40421) performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech FGC 5 (40421) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FGC 5 (40421) / FG | PD ID 2407422 (Qualified 2023-01-27) |
| Duct Connection | 5 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Fantech FGC 5 (40421)?
Calculated coverage metrics translate Fantech FGC 5 (40421) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 149.8 kWh/yr (~$23.97/yr) | 17.1 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Fantech FGC 5 (40421)?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TG-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
Does Fantech FGC 5 (40421) match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech FGC 5 (40421) percentage capacity without sending data.
Where should contractors skip Fantech FGC 5 (40421) on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantech FGC 5 (40421) carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 70 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 120 CFM net static output
- Works well for: Collar pairs with 5 in. diameter duct straight outdoors
Which homeowner questions come up most for Fantech FGC 5 (40421)?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech FGC 5 (40421).
How loud is Fantech FGC 5 (40421) compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Fantech FGC 5 (40421) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Fantech FGC 5 (40421) consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Fantech FGC 5 (40421) draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Fantech FGC 5 (40421) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FGC 5 (40421)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech FGC 5 (40421)?
Fantech FGC 5 (40421) features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech FGC 5 (40421)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FGC 5 (40421)'s safe coverage footprint from 50 sq ft to 44 sq ft.
How does Fantech FGC 5 (40421) score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Fantech FGC 5 (40421) delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Fantech FGC 5 (40421)?
Rule out Fantech FGC 5 (40421) when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Fantech FGC 5 (40421) capacity?
Because static drag at 0.25 in. w.g. lowers Fantech FGC 5 (40421) from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 5 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)