Skip to main content
Grant Estimator

Fantech FG 5 (40404) Exhaust Fan Specifications

ENERGY STAR PD #2407421 · In-line (single-port) · Qualified 2023-01-27
Verified Specification Summary

Tested under HVI protocols, the Fantech FG 5 (40404) exhaust unit achieves 120 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy, covering standard baths up to 120 sq ft on a 5 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 5 (40404) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.0 CFM/W (#420/1,145)
Static Retention
0.1" test only
Motor Draw
17.1 W (6.2 kWh/yr)
Duct & Tier
5 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech FG 5 (40404) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 5 (40404) (EPA filing PD #2407421) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Fantech's 52-unit lineup, FG 5 (40404) (series: FG) carries PD #2407421 dating to 2023-01-27. Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.1 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 149.8 kWh/yr (~$23.97/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

What attic duct routing preserves Fantech FG 5 (40404) CFM output?

Short straight 5 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech FG 5 (40404), preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Fantech FG 5 (40404) measure up on airflow and noise ratings?

Each row below breaks down Fantech FG 5 (40404) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series FG 5 (40404) / FG PD ID 2407421 (Qualified 2023-01-27)
Duct Connection 5 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Fantech FG 5 (40404) CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Fantech FG 5 (40404)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2149.8 kWh/yr (~$23.97/yr)17.1 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Fantech FG 5 (40404)?

Compare Fantech FG 5 (40404) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Tech Drive TD-BF-10 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
Tech Drive TD-BF-10-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
VENTECHLATION BPT14-24TG-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter

Can you size Fantech FG 5 (40404) for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech FG 5 (40404) verified capacity.

Who should not install Fantech FG 5 (40404) in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech FG 5 (40404) for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 120 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around ENERGY STAR sones up to 120 sq ft
  • Primary match: Paired with rigid galvanized 5 in. diameter transition

How do federal and code standards apply to Fantech FG 5 (40404)?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech FG 5 (40404).

Why check Fantech FG 5 (40404) CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech FG 5 (40404) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 5 in. diameter duct runs vital.

How does Fantech FG 5 (40404) sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Fantech FG 5 (40404) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Fantech FG 5 (40404)?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Fantech FG 5 (40404) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 5 (40404)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech FG 5 (40404)?

Fantech FG 5 (40404) features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech FG 5 (40404)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 5 (40404)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Does Fantech FG 5 (40404) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech FG 5 (40404) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Fantech FG 5 (40404) undersized or poorly matched for a bath renovation?

Skip Fantech FG 5 (40404) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories