Tested under HVI protocols, the Fantech FG 5 (40404) exhaust unit achieves 120 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy, covering standard baths up to 120 sq ft on a 5 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 5 (40404) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 120 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.0 CFM/W (#420/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 17.1 W (6.2 kWh/yr)
- Duct & Tier
- 5 in. diameter · Most Eff.

What does Fantech FG 5 (40404) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech FG 5 (40404) (EPA filing PD #2407421) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Fantech's 52-unit lineup, FG 5 (40404) (series: FG) carries PD #2407421 dating to 2023-01-27. Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.1 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 149.8 kWh/yr (~$23.97/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
What attic duct routing preserves Fantech FG 5 (40404) CFM output?
Short straight 5 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech FG 5 (40404), preventing premature peeling paint and mold growth.
How does Fantech FG 5 (40404) measure up on airflow and noise ratings?
Each row below breaks down Fantech FG 5 (40404) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FG 5 (40404) / FG | PD ID 2407421 (Qualified 2023-01-27) |
| Duct Connection | 5 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Fantech FG 5 (40404) CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 149.8 kWh/yr (~$23.97/yr) | 17.1 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Fantech FG 5 (40404)?
Compare Fantech FG 5 (40404) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TG-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
Can you size Fantech FG 5 (40404) for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech FG 5 (40404) verified capacity.
Who should not install Fantech FG 5 (40404) in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech FG 5 (40404) for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 120 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around ENERGY STAR sones up to 120 sq ft
- Primary match: Paired with rigid galvanized 5 in. diameter transition
How do federal and code standards apply to Fantech FG 5 (40404)?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech FG 5 (40404).
Why check Fantech FG 5 (40404) CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech FG 5 (40404) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 5 in. diameter duct runs vital.
How does Fantech FG 5 (40404) sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Fantech FG 5 (40404) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Fantech FG 5 (40404)?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Fantech FG 5 (40404) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 5 (40404)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech FG 5 (40404)?
Fantech FG 5 (40404) features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech FG 5 (40404)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 5 (40404)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Fantech FG 5 (40404) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech FG 5 (40404) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Fantech FG 5 (40404) undersized or poorly matched for a bath renovation?
Skip Fantech FG 5 (40404) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)