Tested under HVI protocols, the Utilitech UTS110120130 exhaust unit achieves 130 CFM at 0.1 in. w.g. (140.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 16.0 CFM/W efficacy, covering standard baths up to 140 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech UTS110120130 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 140.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 16.0 CFM/W (#16/1,145)
- Static Retention
- 108.3% @ 0.25"
- Motor Draw
- 8.1 W (3.0 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Utilitech UTS110120130 vs. 1,145-Model ENERGY STAR Benchmarks show?
Utilitech UTS110120130 (EPA filing PD #4668434) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 140.8 CFM out of 130 CFM (108.3% retention, 20.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Utilitech registers 22 certified models, with SKU UTS110120130 (series: Utilitech) (PD #4668434) certified since 2026-07-08. Lighting kit: No. At 16.0 CFM/W (#16 of 1,145, top 1.5% of 1,145 rated models, more efficient than 98.5% of rated models, 11.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.1 watts, about 3.0 kWh/yr (~$0.48/yr at $0.16/kWh) for 1 hr/day shower timers or 71.0 kWh/yr (~$11.36/yr) continuously. Closest competing matches include Revent RVS110120130 (130.0 CFM) and Revent RVL110120130 (130.0 CFM).
What attic duct routing preserves Utilitech UTS110120130 CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Utilitech UTS110120130, preventing premature peeling paint and mold growth.
How does Utilitech UTS110120130 measure up on airflow and noise ratings?
Each row below breaks down Utilitech UTS110120130 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | UTS110120130 / Utilitech | PD ID 4668434 (Qualified 2026-07-08) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (140.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Utilitech UTS110120130 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 140 sq ft | 1 CFM/sq ft @ 140.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 125 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 90 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.0 kWh/yr (~$0.48/yr) | 8.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 71.0 kWh/yr (~$11.36/yr) | 8.1 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Utilitech UTS110120130?
Compare Utilitech UTS110120130 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVS110120130 | 130 / 140.8 CFM | Unpublished | 16.0 CFM/W | 6 in. diameter |
| Revent RVL110120130 | 130 / 137.2 CFM | Unpublished | 15.8 CFM/W | 6 in. diameter |
| Utilitech UTL110120130 | 130 / 137.2 CFM | Unpublished | 15.8 CFM/W | 6 in. diameter |
| Broan ZB110HL1 | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
| Broan ZB110L1 | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
Can you size Utilitech UTS110120130 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Utilitech UTS110120130 verified capacity.
What plumbing or duct constraints rule out Utilitech UTS110120130?
Compare where Utilitech UTS110120130 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 140.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 140 sq ft
- Suited to: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Utilitech UTS110120130?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Utilitech UTS110120130.
Can Utilitech UTS110120130 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Utilitech UTS110120130 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Utilitech UTS110120130 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Utilitech UTS110120130 lacks adequate reserve.
How does Utilitech UTS110120130 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Utilitech UTS110120130 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is Utilitech UTS110120130 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Utilitech UTS110120130 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Utilitech UTS110120130 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Utilitech UTS110120130 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech UTS110120130's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech UTS110120130?
Utilitech UTS110120130 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech UTS110120130's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech UTS110120130's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)