Skip to main content
Grant Estimator

Utilitech UTL110120130 Exhaust Fan Specifications

ENERGY STAR PD #4668374 · Bathroom/Utility Room · Qualified 2026-07-08
Verified Specification Summary

In EPA dataset 8dv7-nngq, Utilitech UTL110120130 tests at 130 CFM free discharge (137.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 15.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 137 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech UTL110120130 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / 137.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
15.8 CFM/W (#18/1,145)
Static Retention
105.5% @ 0.25"
Motor Draw
8.2 W (3.0 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Utilitech UTL110120130 vs. 1,145-Model ENERGY STAR Benchmarks show?

Utilitech UTL110120130 (EPA filing PD #4668374) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 137.2 CFM out of 130 CFM (105.5% retention, 17.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Utilitech's 22-unit lineup, UTL110120130 (series: Utilitech) carries PD #4668374 dating to 2026-07-08. Lighting kit: Yes. At 15.8 CFM/W (#18 of 1,145, top 1.7% of 1,145 rated models, more efficient than 98.3% of rated models, 11.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.2 watts, about 3.0 kWh/yr (~$0.48/yr at $0.16/kWh) for 1 hr/day shower timers or 71.8 kWh/yr (~$11.49/yr) continuously. Closest competing matches include Revent RVL110120130 (130.0 CFM) and Revent RVS110120130 (130.0 CFM).

Why avoid unvented attic termination with Utilitech UTL110120130?

Under ASHRAE 62.2 best practice, Utilitech UTL110120130 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Utilitech UTL110120130?

Before cutting ceiling drywall or sizing attic transitions for Utilitech UTL110120130, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Utilitech (22 models) ENERGY STAR Certified Partner
Model Number & Series UTL110120130 / Utilitech PD ID 4668374 (Qualified 2026-07-08)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (137.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Utilitech UTL110120130?

Bathroom ventilation sizing below maps Utilitech UTL110120130 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Utilitech UTL110120130
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 137 sq ft1 CFM/sq ft @ 137.2 CFM
Tall Bath (9-ft Ceiling)Up to 121 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 87 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.0 kWh/yr (~$0.48/yr)8.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.271.8 kWh/yr (~$11.49/yr)8.2 W x 8,760 hrs / 1,000

What peer models sit nearest Utilitech UTL110120130 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Utilitech UTL110120130.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110120130 130 / 137.2 CFM Unpublished 15.8 CFM/W 6 in. diameter
Revent RVS110120130 130 / 140.8 CFM Unpublished 16.0 CFM/W 6 in. diameter
Utilitech UTS110120130 130 / 140.8 CFM Unpublished 16.0 CFM/W 6 in. diameter
Panasonic FV-0511VKL3 110 / 114.4 CFM Unpublished 15.7 CFM/W 6 in. diameter
Panasonic FV-0511VKSL3 110 / 114.4 CFM Unpublished 15.7 CFM/W 6 in. diameter

What percentage of room demand does Utilitech UTL110120130 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Utilitech UTL110120130 tested delivery.

Where should contractors skip Utilitech UTL110120130 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Utilitech UTL110120130 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 137.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around ENERGY STAR sones up to 137 sq ft
  • Works well for: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Utilitech UTL110120130?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Utilitech UTL110120130.

How loud is Utilitech UTL110120130 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Utilitech UTL110120130 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Utilitech UTL110120130 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Utilitech UTL110120130 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Utilitech UTL110120130 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech UTL110120130's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Utilitech UTL110120130?

Utilitech UTL110120130 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Utilitech UTL110120130's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech UTL110120130's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Utilitech UTL110120130 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Utilitech UTL110120130 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Utilitech UTL110120130?

Rule out Utilitech UTL110120130 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Utilitech UTL110120130 capacity?

Because static drag at 0.25 in. w.g. lowers Utilitech UTL110120130 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories