Panasonic Eco Solutions FV-1315RQ1 Exhaust Fan Specifications

ENERGY STAR PD #2390257 · Bathroom/Utility Room · Qualified 2022-01-07
Verified Specification Summary

Tested under HVI protocols, the Panasonic Eco Solutions FV-1315RQ1 exhaust unit achieves 150 CFM at 0.1 in. w.g. (122.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, covering standard baths up to 122 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic Eco Solutions FV-1315RQ1 Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
150 / 122.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.5 CFM/W (#471/1,145)
Static Retention
81.6% @ 0.25"
Motor Draw
27.3 W (10.0 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic Eco Solutions FV-1315RQ1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic Eco Solutions FV-1315RQ1 (EPA filing PD #2390257) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 122.4 CFM at 0.25 in. w.g. (81.6% retention, 6.1 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Panasonic Eco Solutions maintains 9 active ENERGY STAR blowers; FV-1315RQ1 (series: Whisper Choice) (PD #2390257) gained qualification on 2022-01-07. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.3 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 239.1 kWh/yr (~$38.26/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

What attic duct routing preserves Panasonic Eco Solutions FV-1315RQ1 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic Eco Solutions FV-1315RQ1, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Panasonic Eco Solutions FV-1315RQ1 measure up on airflow and noise ratings?

Each row below breaks down Panasonic Eco Solutions FV-1315RQ1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic Eco Solutions (9 models) ENERGY STAR Certified Partner
Model Number & Series FV-1315RQ1 / Whisper Choice PD ID 2390257 (Qualified 2022-01-07)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (122.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Panasonic Eco Solutions FV-1315RQ1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic Eco Solutions FV-1315RQ1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 122 sq ft1 CFM/sq ft @ 122.4 CFM
Tall Bath (9-ft Ceiling)Up to 108 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 72 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.0 kWh/yr (~$1.60/yr)27.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2239.1 kWh/yr (~$38.26/yr)27.3 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Panasonic Eco Solutions FV-1315RQ1?

Compare Panasonic Eco Solutions FV-1315RQ1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter

Can you size Panasonic Eco Solutions FV-1315RQ1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic Eco Solutions FV-1315RQ1 verified capacity.

What plumbing or duct constraints rule out Panasonic Eco Solutions FV-1315RQ1?

Compare where Panasonic Eco Solutions FV-1315RQ1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 122.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around ENERGY STAR sones up to 122 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Panasonic Eco Solutions FV-1315RQ1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic Eco Solutions FV-1315RQ1.

Is Panasonic Eco Solutions FV-1315RQ1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Panasonic Eco Solutions FV-1315RQ1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic Eco Solutions FV-1315RQ1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic Eco Solutions FV-1315RQ1?

Panasonic Eco Solutions FV-1315RQ1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic Eco Solutions FV-1315RQ1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic Eco Solutions FV-1315RQ1's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Panasonic Eco Solutions FV-1315RQ1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic Eco Solutions FV-1315RQ1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Panasonic Eco Solutions FV-1315RQ1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic Eco Solutions FV-1315RQ1 lacks adequate reserve.

How does Panasonic Eco Solutions FV-1315RQ1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic Eco Solutions FV-1315RQ1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Panasonic Eco Solutions FV-1315RQ1 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic Eco Solutions FV-1315RQ1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)