Panasonic FV-0511VFBL1 Exhaust Fan Specifications

ENERGY STAR PD #4510686 · Bathroom/Utility Room · Qualified 2025-09-05
Verified Specification Summary

Tested under HVI protocols, the Panasonic FV-0511VFBL1 exhaust unit achieves 110 CFM at 0.1 in. w.g. (91.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 6.4 CFM/W efficacy, covering standard baths up to 91 sq ft on a 3 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFBL1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 91.7 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
6.4 CFM/W (#438/1,145)
Static Retention
83.4% @ 0.25"
Motor Draw
17.2 W (6.3 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VFBL1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFBL1 (EPA filing PD #4510686) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 91.7 CFM at 0.25 in. w.g. (83.4% retention, 4.3 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places FV-0511VFBL1 (series: WhisperFit DC with speaker) (PD #4510686) among 92 Panasonic entries qualified through 2025-09-05. Lighting kit: Yes. At 6.4 CFM/W (#438 of 1,145, top 38.8% of 1,145 rated models, more efficient than 61.2% of rated models, 1.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7115-01 (100.0 CFM).

What attic duct routing preserves Panasonic FV-0511VFBL1 CFM output?

Short straight 3 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-0511VFBL1, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Panasonic FV-0511VFBL1 measure up on airflow and noise ratings?

Each row below breaks down Panasonic FV-0511VFBL1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VFBL1 / WhisperFit DC with speaker PD ID 4510686 (Qualified 2025-09-05)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (91.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Panasonic FV-0511VFBL1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFBL1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 91 sq ft1 CFM/sq ft @ 91.7 CFM
Tall Bath (9-ft Ceiling)Up to 81 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 41 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.3 kWh/yr (~$1.01/yr)17.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2150.7 kWh/yr (~$24.11/yr)17.2 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Panasonic FV-0511VFBL1?

Compare Panasonic FV-0511VFBL1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech 7115-01 100 / 95.4 CFM 1.5 sones 6.5 CFM/W 4 in. diameter
Tech Drive TD-BF-10 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
Tech Drive TD-BF-10-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
VENTECHLATION BPT14-24TG-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter

Can you size Panasonic FV-0511VFBL1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-0511VFBL1 verified capacity.

When does Panasonic FV-0511VFBL1 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic FV-0511VFBL1.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 91.7 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 91 sq ft
  • Target scenario: Paired with rigid galvanized 3 in. diameter transition

How do federal and code standards apply to Panasonic FV-0511VFBL1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-0511VFBL1.

Will Panasonic FV-0511VFBL1 disturb adjacent bedrooms during night use?

Acoustic measurement places Panasonic FV-0511VFBL1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Panasonic FV-0511VFBL1 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Panasonic FV-0511VFBL1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Panasonic FV-0511VFBL1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFBL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VFBL1?

Panasonic FV-0511VFBL1 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VFBL1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFBL1's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Panasonic FV-0511VFBL1 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFBL1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Panasonic FV-0511VFBL1?

Do not force Panasonic FV-0511VFBL1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Panasonic FV-0511VFBL1 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Panasonic FV-0511VFBL1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.