Skip to main content
Grant Estimator

Panasonic FV-0511VFC1 Exhaust Fan Specifications

ENERGY STAR PD #2381483 · Bathroom/Utility Room · Qualified 2021-04-30
Verified Specification Summary

Rated for 110 CFM open-air (96.6 CFM at 0.25 in. w.g.), Panasonic FV-0511VFC1 omits a published 0.1-inch sone rating and delivers 6.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 96 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFC1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 96.6 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
6.6 CFM/W (#433/1,145)
Static Retention
87.8% @ 0.25"
Motor Draw
16.7 W (6.1 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VFC1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFC1 (EPA filing PD #2381483) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 96.6 CFM out of 110 CFM (87.8% retention, 0.1 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Panasonic FV-0511VFC1 (series: WhisperFit DC) under PD #2381483 (92 models registered, 2021-04-30). Lighting kit: No. At 6.6 CFM/W (#433 of 1,145, top 38.0% of 1,145 rated models, more efficient than 62.0% of rated models, 1.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7115-01 (100.0 CFM).

How do flex elbows choke Panasonic FV-0511VFC1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Panasonic FV-0511VFC1 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Panasonic FV-0511VFC1 meet residential exhaust fan code specs?

Inspect Panasonic FV-0511VFC1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VFC1 / WhisperFit DC PD ID 2381483 (Qualified 2021-04-30)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (96.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Panasonic FV-0511VFC1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Panasonic FV-0511VFC1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFC1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 96 sq ft1 CFM/sq ft @ 96.6 CFM
Tall Bath (9-ft Ceiling)Up to 85 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 46 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.1 kWh/yr (~$0.98/yr)16.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2146.3 kWh/yr (~$23.41/yr)16.7 W x 8,760 hrs / 1,000

Which competing models share Panasonic FV-0511VFC1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech 7115-01 100 / 95.4 CFM 1.5 sones 6.5 CFM/W 4 in. diameter
Delta 100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta GBR100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta ITG100 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter

How much airflow margin does Panasonic FV-0511VFC1 give your bath?

Run a quick local room-volume check for Panasonic FV-0511VFC1 by entering square footage and ceiling height to spot under-vented steam risks early.

Does Panasonic FV-0511VFC1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-0511VFC1 for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 46 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 96 sq ft with 8-ft ceilings (85 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 3 in. diameter

What should homeowners verify first about Panasonic FV-0511VFC1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic FV-0511VFC1.

Who should NOT install Panasonic FV-0511VFC1 in a bathroom remodel?

Avoid specifying Panasonic FV-0511VFC1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Panasonic FV-0511VFC1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-0511VFC1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Panasonic FV-0511VFC1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-0511VFC1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Panasonic FV-0511VFC1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-0511VFC1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Panasonic FV-0511VFC1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFC1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VFC1?

Panasonic FV-0511VFC1 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VFC1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFC1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Panasonic FV-0511VFC1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFC1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories