Certified by EPA ENERGY STAR, Revent RVSC120140160 delivers 160 CFM free-air (164.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 164 sq ft (8-ft height) or 146 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVSC120140160 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 160 / 164.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.9 CFM/W (#138/1,145)
- Static Retention
- 102.9% @ 0.25"
- Motor Draw
- 14.7 W (5.4 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Revent RVSC120140160 vs. 1,145-Model ENERGY STAR Benchmarks show?
Revent RVSC120140160 (EPA filing PD #4717294) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 164.7 CFM out of 160 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #4717294 verifies RVSC120140160 (series: ReVent) under Revent (40 listed models, qualified 2026-10-07). Lighting kit: No. At 10.9 CFM/W (#138 of 1,145, top 12.1% of 1,145 rated models, more efficient than 87.9% of rated models, 6.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.7 watts, about 5.4 kWh/yr (~$0.86/yr at $0.16/kWh) for 1 hr/day shower timers or 128.8 kWh/yr (~$20.61/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 300 (167.0 CFM).
Why does rigid 6 in. diameter ducting protect Revent RVSC120140160 airflow?
Connecting Revent RVSC120140160 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Revent RVSC120140160 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Revent RVSC120140160 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVSC120140160 / ReVent | PD ID 4717294 (Qualified 2026-10-07) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (164.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Revent RVSC120140160?
Calculated coverage metrics translate Revent RVSC120140160 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 164 sq ft | 1 CFM/sq ft @ 164.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 146 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 114 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.4 kWh/yr (~$0.86/yr) | 14.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 128.8 kWh/yr (~$20.61/yr) | 14.7 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Revent RVSC120140160?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 300 | 167 / N/A CFM | 1.9 sones | 9.9 CFM/W | 8 x 6 in. rectangular |
| Broan QTXE110150DC | 150 / 147.8 CFM | Unpublished | 11.0 CFM/W | 6 in. diameter |
| Broan QTXE110150DC=QTXEDCH with QTXE110150DCF | 150 / 147.8 CFM | Unpublished | 11.0 CFM/W | 6 in. diameter |
| Broan QTXE110150DCL | 150 / 147.8 CFM | Unpublished | 11.0 CFM/W | 6 in. diameter |
Does Revent RVSC120140160 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Revent RVSC120140160 percentage capacity without sending data.
Does Revent RVSC120140160 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Revent RVSC120140160 for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 114 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 164.7 CFM net static output
- Best application: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for Revent RVSC120140160?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Revent RVSC120140160.
Does Revent RVSC120140160 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Revent RVSC120140160 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Revent RVSC120140160 in a bathroom remodel?
Avoid specifying Revent RVSC120140160 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Revent RVSC120140160 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Revent RVSC120140160 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Revent RVSC120140160 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Revent RVSC120140160 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Revent RVSC120140160 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Revent RVSC120140160 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Revent RVSC120140160 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVSC120140160's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVSC120140160?
Revent RVSC120140160 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVSC120140160's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVSC120140160's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)