Rated for 160 CFM open-air (unpublished 0.25 in. w.g. output), S&P TD-125 omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 160 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P TD-125 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 160 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 35.6 W (13.0 kWh/yr)
- Duct & Tier
- 5 in. diameter · Standard

What does S&P TD-125 vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P TD-125 (EPA filing PD #2381146) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
S&P maintains 29 active ENERGY STAR blowers; TD-125 (series: TD) (PD #2381146) gained qualification on 2021-06-25. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.6 watts, about 13.0 kWh/yr (~$2.08/yr at $0.16/kWh) for 1 hr/day shower timers or 311.9 kWh/yr (~$49.90/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and Broan QT150LE (150.0 CFM).
How do flex elbows choke S&P TD-125 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 5 in. diameter metal pipe keeps S&P TD-125 moving full rated CFM.
Does S&P TD-125 meet residential exhaust fan code specs?
Inspect S&P TD-125 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-125 / TD | PD ID 2381146 (Qualified 2021-06-25) |
| Duct Connection | 5 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (160 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match S&P TD-125 airflow output?
Annual electricity figures and room square-footage ceilings below reflect S&P TD-125 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 160 sq ft | 1 CFM/sq ft @ 160 CFM |
| Tall Bath (9-ft Ceiling) | Up to 142 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 110 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 13.0 kWh/yr (~$2.08/yr) | 35.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 311.9 kWh/yr (~$49.90/yr) | 35.6 W x 8,760 hrs / 1,000 |
Which competing models share S&P TD-125 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Tech Drive TD-BF-19 | 160 / 138.2 CFM | 1.0 sones | 4.5 CFM/W | 6 in. diameter |
How much airflow margin does S&P TD-125 give your bath?
Run a quick local room-volume check for S&P TD-125 by entering square footage and ceiling height to spot under-vented steam risks early.
When does S&P TD-125 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering S&P TD-125.
Limitations & Who Should Skip
- Steam or walk-in tub room > 110 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 160 sq ft with 8-ft ceilings (142 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 5 in. diameter
What should homeowners verify first about S&P TD-125?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to S&P TD-125.
Which bathroom layouts should pick a larger blower than S&P TD-125?
Do not force S&P TD-125 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does S&P TD-125 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, S&P TD-125 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 5 in. diameter metal duct transitions.
Will S&P TD-125 disturb adjacent bedrooms during night use?
Acoustic measurement places S&P TD-125 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running S&P TD-125 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of S&P TD-125 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can S&P TD-125 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P TD-125's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P TD-125?
S&P TD-125 features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P TD-125's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P TD-125's safe coverage footprint from 50 sq ft to 44 sq ft.
Is S&P TD-125 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), S&P TD-125 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.