Revent RVSH80110 Exhaust Fan Specifications

ENERGY STAR PD #4517834 · Bathroom/Utility Room · Qualified 2025-10-03
Verified Specification Summary

Certified by EPA ENERGY STAR, Revent RVSH80110 delivers 110 CFM free-air (121.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 12.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 121 sq ft (8-ft height) or 107 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVSH80110 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 121.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
12.0 CFM/W (#80/1,145)
Static Retention
110.1% @ 0.25"
Motor Draw
9.2 W (3.4 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVSH80110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent RVSH80110 (EPA filing PD #4517834) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 121.1 CFM out of 110 CFM (110.1% retention, 22.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Revent RVSH80110 (series: ReVent) under PD #4517834 (40 models registered, 2025-10-03). Lighting kit: No. At 12.0 CFM/W (#80 of 1,145, top 7.3% of 1,145 rated models, more efficient than 92.7% of rated models, 7.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.2 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 80.6 kWh/yr (~$12.90/yr) continuously. Closest competing matches include DewStop - Breeze Easy BEL110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

Why does rigid 4 in. diameter ducting protect Revent RVSH80110 airflow?

Connecting Revent RVSH80110 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Revent RVSH80110 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Revent RVSH80110 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVSH80110 / ReVent PD ID 4517834 (Qualified 2025-10-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (121.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Revent RVSH80110?

Calculated coverage metrics translate Revent RVSH80110 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Revent RVSH80110
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 121 sq ft1 CFM/sq ft @ 121.1 CFM
Tall Bath (9-ft Ceiling)Up to 107 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 71 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.4 kWh/yr (~$0.54/yr)9.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.280.6 kWh/yr (~$12.90/yr)9.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Revent RVSH80110?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter

Does Revent RVSH80110 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Revent RVSH80110 percentage capacity without sending data.

Which bath layouts should avoid specifying Revent RVSH80110?

Match Revent RVSH80110 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 71 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 121.1 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Revent RVSH80110?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Revent RVSH80110.

What happens to Revent RVSH80110 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Revent RVSH80110 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Revent RVSH80110 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Revent RVSH80110 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Revent RVSH80110 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Revent RVSH80110 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Revent RVSH80110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVSH80110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVSH80110?

Revent RVSH80110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVSH80110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVSH80110's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Revent RVSH80110 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Revent RVSH80110 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Revent RVSH80110 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Revent RVSH80110.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories