Broan LP50100DC Exhaust Fan Specifications

ENERGY STAR PD #2340590 · Bathroom/Utility Room · Qualified 2019-06-28
Verified Specification Summary

Homeowners specifying Broan LP50100DC gain 100 CFM at 0.1 in. w.g. (104.5 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 10.5 CFM/W efficacy, venting bathrooms up to 104 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan LP50100DC Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 104.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
10.5 CFM/W (#158/1,145)
Static Retention
104.5% @ 0.25"
Motor Draw
9.5 W (3.5 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan LP50100DC vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan LP50100DC (EPA filing PD #2340590) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 104.5 CFM out of 100 CFM (104.5% retention, 16.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2340590 verifies LP50100DC (series: LOPROFILE DC) under Broan (207 listed models, qualified 2019-06-28). Lighting kit: No. At 10.5 CFM/W (#158 of 1,145, top 14.8% of 1,145 rated models, more efficient than 85.2% of rated models, 5.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.5 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 83.2 kWh/yr (~$13.31/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Delta GBR100LED-DECOR (100.0 CFM).

Which exterior damper path suits Broan LP50100DC best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan LP50100DC housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan LP50100DC acoustic and static metrics stand?

Compare Broan LP50100DC published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series LP50100DC / LOPROFILE DC PD ID 2340590 (Qualified 2019-06-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (104.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Broan LP50100DC handle taller ceilings or walk-in tub steam?

Evaluate how Broan LP50100DC scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan LP50100DC
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 104 sq ft1 CFM/sq ft @ 104.5 CFM
Tall Bath (9-ft Ceiling)Up to 92 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 54 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.5 kWh/yr (~$0.56/yr)9.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.283.2 kWh/yr (~$13.31/yr)9.5 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan LP50100DC?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Is Broan LP50100DC sized right for your shower or tub room?

Check whether Broan LP50100DC clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Broan LP50100DC suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan LP50100DC for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 54 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 104.5 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan LP50100DC?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan LP50100DC.

How many kWh per year does Broan LP50100DC add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan LP50100DC averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan LP50100DC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan LP50100DC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan LP50100DC?

Broan LP50100DC features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan LP50100DC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan LP50100DC's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan LP50100DC pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan LP50100DC easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan LP50100DC in a bathroom remodel?

Avoid specifying Broan LP50100DC in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan LP50100DC airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan LP50100DC achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan LP50100DC occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan LP50100DC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories