Skip to main content
Grant Estimator

ACIQ ANPD100-3 Exhaust Fan Specifications

ENERGY STAR PD #3998905 · Bathroom/Utility Room · Qualified 2025-01-24
Verified Specification Summary

Homeowners specifying ACIQ ANPD100-3 gain 100 CFM at 0.1 in. w.g. (103.8 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 11.1 CFM/W efficacy, venting bathrooms up to 103 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ ANPD100-3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 103.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.1 CFM/W (#128/1,145)
Static Retention
103.8% @ 0.25"
Motor Draw
9.0 W (3.3 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does ACIQ ANPD100-3 vs. 1,145-Model ENERGY STAR Benchmarks show?

ACIQ ANPD100-3 (EPA filing PD #3998905) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 103.8 CFM out of 100 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3998905 verifies ANPD100-3 (series: ANPD) under ACIQ (15 listed models, qualified 2025-01-24). Lighting kit: No. At 11.1 CFM/W (#128 of 1,145, top 11.4% of 1,145 rated models, more efficient than 88.6% of rated models, 6.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.0 watts, about 3.3 kWh/yr (~$0.53/yr at $0.16/kWh) for 1 hr/day shower timers or 78.8 kWh/yr (~$12.61/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

Which exterior damper path suits ACIQ ANPD100-3 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around ACIQ ANPD100-3 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do ACIQ ANPD100-3 acoustic and static metrics stand?

Compare ACIQ ANPD100-3 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share ACIQ (15 models) ENERGY STAR Certified Partner
Model Number & Series ANPD100-3 / ANPD PD ID 3998905 (Qualified 2025-01-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (103.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can ACIQ ANPD100-3 handle taller ceilings or walk-in tub steam?

Evaluate how ACIQ ANPD100-3 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for ACIQ ANPD100-3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 103 sq ft1 CFM/sq ft @ 103.8 CFM
Tall Bath (9-ft Ceiling)Up to 92 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 53 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.3 kWh/yr (~$0.53/yr)9.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.278.8 kWh/yr (~$12.61/yr)9.0 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near ACIQ ANPD100-3?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter

Is ACIQ ANPD100-3 sized right for your shower or tub room?

Check whether ACIQ ANPD100-3 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does ACIQ ANPD100-3 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying ACIQ ANPD100-3 for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 53 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 103.8 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for ACIQ ANPD100-3?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to ACIQ ANPD100-3.

How many kWh per year does ACIQ ANPD100-3 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, ACIQ ANPD100-3 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can ACIQ ANPD100-3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ ANPD100-3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing ACIQ ANPD100-3?

ACIQ ANPD100-3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change ACIQ ANPD100-3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ ANPD100-3's safe coverage footprint from 50 sq ft to 44 sq ft.

Does ACIQ ANPD100-3 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), ACIQ ANPD100-3 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install ACIQ ANPD100-3 in a bathroom remodel?

Avoid specifying ACIQ ANPD100-3 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut ACIQ ANPD100-3 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, ACIQ ANPD100-3 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does ACIQ ANPD100-3 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., ACIQ ANPD100-3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories