Tested under HVI protocols, the Broan LP50100DC=LPDCH with LP50100DCF exhaust unit achieves 100 CFM at 0.1 in. w.g. (104.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 10.5 CFM/W efficacy, covering standard baths up to 104 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan LP50100DC=LPDCH with LP50100DCF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 104.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.5 CFM/W (#158/1,145)
- Static Retention
- 104.5% @ 0.25"
- Motor Draw
- 9.5 W (3.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Broan LP50100DC=LPDCH with LP50100DCF vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan LP50100DC=LPDCH with LP50100DCF (EPA filing PD #2340589) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 104.5 CFM out of 100 CFM (104.5% retention, 16.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places LP50100DC=LPDCH with LP50100DCF (series: LOPROFILE DC) (PD #2340589) among 207 Broan entries qualified through 2019-06-28. Lighting kit: No. At 10.5 CFM/W (#158 of 1,145, top 14.8% of 1,145 rated models, more efficient than 85.2% of rated models, 5.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.5 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 83.2 kWh/yr (~$13.31/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Delta GBR100LED-DECOR (100.0 CFM).
What attic duct routing preserves Broan LP50100DC=LPDCH with LP50100DCF CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan LP50100DC=LPDCH with LP50100DCF, preventing premature peeling paint and mold growth.
How does Broan LP50100DC=LPDCH with LP50100DCF measure up on airflow and noise ratings?
Each row below breaks down Broan LP50100DC=LPDCH with LP50100DCF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | LP50100DC=LPDCH with LP50100DCF / LOPROFILE DC | PD ID 2340589 (Qualified 2019-06-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (104.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan LP50100DC=LPDCH with LP50100DCF CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 104 sq ft | 1 CFM/sq ft @ 104.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 54 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.5 kWh/yr (~$0.56/yr) | 9.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 83.2 kWh/yr (~$13.31/yr) | 9.5 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan LP50100DC=LPDCH with LP50100DCF?
Compare Broan LP50100DC=LPDCH with LP50100DCF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Can you size Broan LP50100DC=LPDCH with LP50100DCF for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan LP50100DC=LPDCH with LP50100DCF verified capacity.
When does Broan LP50100DC=LPDCH with LP50100DCF fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan LP50100DC=LPDCH with LP50100DCF.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 104.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 104 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Broan LP50100DC=LPDCH with LP50100DCF?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan LP50100DC=LPDCH with LP50100DCF.
Is Broan LP50100DC=LPDCH with LP50100DCF code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan LP50100DC=LPDCH with LP50100DCF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan LP50100DC=LPDCH with LP50100DCF?
Do not force Broan LP50100DC=LPDCH with LP50100DCF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan LP50100DC=LPDCH with LP50100DCF retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan LP50100DC=LPDCH with LP50100DCF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Broan LP50100DC=LPDCH with LP50100DCF disturb adjacent bedrooms during night use?
Acoustic measurement places Broan LP50100DC=LPDCH with LP50100DCF at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan LP50100DC=LPDCH with LP50100DCF continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan LP50100DC=LPDCH with LP50100DCF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan LP50100DC=LPDCH with LP50100DCF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan LP50100DC=LPDCH with LP50100DCF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan LP50100DC=LPDCH with LP50100DCF?
Broan LP50100DC=LPDCH with LP50100DCF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan LP50100DC=LPDCH with LP50100DCF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan LP50100DC=LPDCH with LP50100DCF's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)