Tested under HVI protocols, the CFM TF100-EC exhaust unit achieves 100 CFM at 0.1 in. w.g. (103.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.1 CFM/W efficacy, covering standard baths up to 103 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside CFM TF100-EC Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 103.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 11.1 CFM/W (#128/1,145)
- Static Retention
- 103.8% @ 0.25"
- Motor Draw
- 9.0 W (3.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does CFM TF100-EC vs. 1,145-Model ENERGY STAR Benchmarks show?
CFM TF100-EC (EPA filing PD #2624892) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 103.8 CFM out of 100 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms CFM TF100-EC (series: TF) under PD #2624892 (4 models registered, 2023-07-28). Lighting kit: No. At 11.1 CFM/W (#128 of 1,145, top 11.4% of 1,145 rated models, more efficient than 88.6% of rated models, 6.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.0 watts, about 3.3 kWh/yr (~$0.53/yr at $0.16/kWh) for 1 hr/day shower timers or 78.8 kWh/yr (~$12.61/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
What attic duct routing preserves CFM TF100-EC CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on CFM TF100-EC, preventing premature peeling paint and mold growth.
How does CFM TF100-EC measure up on airflow and noise ratings?
Each row below breaks down CFM TF100-EC certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | CFM (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TF100-EC / TF | PD ID 2624892 (Qualified 2023-07-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (103.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect CFM TF100-EC CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.3 kWh/yr (~$0.53/yr) | 9.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 78.8 kWh/yr (~$12.61/yr) | 9.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against CFM TF100-EC?
Compare CFM TF100-EC side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
Can you size CFM TF100-EC for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against CFM TF100-EC verified capacity.
What plumbing or duct constraints rule out CFM TF100-EC?
Compare where CFM TF100-EC excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 103.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 103 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to CFM TF100-EC?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for CFM TF100-EC.
Is CFM TF100-EC quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, CFM TF100-EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is CFM TF100-EC energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can CFM TF100-EC pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from CFM TF100-EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing CFM TF100-EC?
CFM TF100-EC features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change CFM TF100-EC's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing CFM TF100-EC's safe coverage footprint from 50 sq ft to 44 sq ft.
Can CFM TF100-EC serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: CFM TF100-EC supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap CFM TF100-EC for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, CFM TF100-EC lacks adequate reserve.
How does CFM TF100-EC handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., CFM TF100-EC yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)