Rated for 100 CFM open-air (84.7 CFM at 0.25 in. w.g.), Cyclone CBPD3S100H omits a published 0.1-inch sone rating and delivers 13.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 84 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CBPD3S100H Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 84.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 13.2 CFM/W (#49/1,145)
- Static Retention
- 84.7% @ 0.25"
- Motor Draw
- 7.6 W (2.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Cyclone CBPD3S100H vs. 1,145-Model ENERGY STAR Benchmarks show?
Cyclone CBPD3S100H (EPA filing PD #3626821) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.7 CFM at 0.25 in. w.g. (84.7% retention, 3.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Cyclone registers 17 certified models, with SKU CBPD3S100H (series: CBPD) (PD #3626821) certified since 2024-07-12. Lighting kit: No. At 13.2 CFM/W (#49 of 1,145, top 4.5% of 1,145 rated models, more efficient than 95.5% of rated models, 8.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.6 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 66.6 kWh/yr (~$10.66/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).
How do flex elbows choke Cyclone CBPD3S100H at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Cyclone CBPD3S100H moving full rated CFM.
Does Cyclone CBPD3S100H meet residential exhaust fan code specs?
Inspect Cyclone CBPD3S100H mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Cyclone (17 models) | ENERGY STAR Certified Partner |
| Model Number & Series | CBPD3S100H / CBPD | PD ID 3626821 (Qualified 2024-07-12) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (84.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Cyclone CBPD3S100H airflow output?
Annual electricity figures and room square-footage ceilings below reflect Cyclone CBPD3S100H tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.8 kWh/yr (~$0.45/yr) | 7.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 66.6 kWh/yr (~$10.66/yr) | 7.6 W x 8,760 hrs / 1,000 |
Which competing models share Cyclone CBPD3S100H airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVS8090100 | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
| Utilitech UTS8090100 | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
How much airflow margin does Cyclone CBPD3S100H give your bath?
Run a quick local room-volume check for Cyclone CBPD3S100H by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Cyclone CBPD3S100H in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Cyclone CBPD3S100H for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 84 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Cyclone CBPD3S100H?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Cyclone CBPD3S100H.
How does Cyclone CBPD3S100H sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Cyclone CBPD3S100H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Cyclone CBPD3S100H?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Cyclone CBPD3S100H pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CBPD3S100H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Cyclone CBPD3S100H?
Cyclone CBPD3S100H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Cyclone CBPD3S100H's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CBPD3S100H's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Cyclone CBPD3S100H satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Cyclone CBPD3S100H clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Cyclone CBPD3S100H undersized or poorly matched for a bath renovation?
Skip Cyclone CBPD3S100H if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Cyclone CBPD3S100H CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Cyclone CBPD3S100H registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)