Certified by EPA ENERGY STAR, Utilitech UTS8090100 delivers 100 CFM free-air (108.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 12.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 108 sq ft (8-ft height) or 96 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech UTS8090100 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 108.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 12.7 CFM/W (#64/1,145)
- Static Retention
- 108.5% @ 0.25"
- Motor Draw
- 7.9 W (2.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Utilitech UTS8090100 vs. 1,145-Model ENERGY STAR Benchmarks show?
Utilitech UTS8090100 (EPA filing PD #4668454) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108.5 CFM out of 100 CFM (108.5% retention, 20.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Utilitech registers 22 certified models, with SKU UTS8090100 (series: Utilitech) (PD #4668454) certified since 2026-07-08. Lighting kit: No. At 12.7 CFM/W (#64 of 1,145, top 5.7% of 1,145 rated models, more efficient than 94.3% of rated models, 8.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.9 watts, about 2.9 kWh/yr (~$0.46/yr at $0.16/kWh) for 1 hr/day shower timers or 69.2 kWh/yr (~$11.07/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).
Why does rigid 4 in. diameter ducting protect Utilitech UTS8090100 airflow?
Connecting Utilitech UTS8090100 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Utilitech UTS8090100 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Utilitech UTS8090100 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | UTS8090100 / Utilitech | PD ID 4668454 (Qualified 2026-07-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (108.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Utilitech UTS8090100?
Calculated coverage metrics translate Utilitech UTS8090100 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 108 sq ft | 1 CFM/sq ft @ 108.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 58 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.9 kWh/yr (~$0.46/yr) | 7.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 69.2 kWh/yr (~$11.07/yr) | 7.9 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Utilitech UTS8090100?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVS8090100 | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
| Revent RVL8090100 | 100 / 109.2 CFM | Unpublished | 12.5 CFM/W | 4 in. diameter |
Does Utilitech UTS8090100 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Utilitech UTS8090100 percentage capacity without sending data.
What plumbing or duct constraints rule out Utilitech UTS8090100?
Compare where Utilitech UTS8090100 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 58 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 108.5 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Utilitech UTS8090100?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Utilitech UTS8090100.
Is Utilitech UTS8090100 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Utilitech UTS8090100 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech UTS8090100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech UTS8090100?
Utilitech UTS8090100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech UTS8090100's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech UTS8090100's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Utilitech UTS8090100 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Utilitech UTS8090100 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Utilitech UTS8090100 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Utilitech UTS8090100 lacks adequate reserve.
How does Utilitech UTS8090100 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Utilitech UTS8090100 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Utilitech UTS8090100 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Utilitech UTS8090100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)