Rated for 80 CFM open-air (84.8 CFM at 0.25 in. w.g.), S&P PCD80XHP omits a published 0.1-inch sone rating and delivers 14.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 84 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCD80XHP Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 84.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 14.4 CFM/W (#33/1,145)
- Static Retention
- 106.0% @ 0.25"
- Motor Draw
- 5.6 W (2.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does S&P PCD80XHP vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P PCD80XHP (EPA filing PD #2397155) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 84.8 CFM out of 80 CFM (106.0% retention, 18.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: S&P registers 29 certified models, with SKU PCD80XHP (series: PCD) (PD #2397155) certified since 2022-05-20. Lighting kit: No. At 14.4 CFM/W (#33 of 1,145, top 2.9% of 1,145 rated models, more efficient than 97.1% of rated models, 9.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 5.6 watts, about 2.0 kWh/yr (~$0.32/yr at $0.16/kWh) for 1 hr/day shower timers or 49.1 kWh/yr (~$7.86/yr) continuously. Closest competing matches include Cyclone CTLD100 (100.0 CFM) and Cyclone CBPD3S100 (100.0 CFM).
How do flex elbows choke S&P PCD80XHP at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps S&P PCD80XHP moving full rated CFM.
Does S&P PCD80XHP meet residential exhaust fan code specs?
Inspect S&P PCD80XHP mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PCD80XHP / PCD | PD ID 2397155 (Qualified 2022-05-20) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (84.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match S&P PCD80XHP airflow output?
Annual electricity figures and room square-footage ceilings below reflect S&P PCD80XHP tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.0 kWh/yr (~$0.32/yr) | 5.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 49.1 kWh/yr (~$7.86/yr) | 5.6 W x 8,760 hrs / 1,000 |
Which competing models share S&P PCD80XHP airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Cyclone CTLD100 | 100 / 84.7 CFM | Unpublished | 13.3 CFM/W | 4 in. diameter |
| Cyclone CBPD3S100 | 100 / 84.7 CFM | Unpublished | 13.2 CFM/W | 4 in. diameter |
| Cyclone CBPD3S100H | 100 / 84.7 CFM | Unpublished | 13.2 CFM/W | 4 in. diameter |
| Revent RVS8090100 | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
| Utilitech UTS8090100 | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
How much airflow margin does S&P PCD80XHP give your bath?
Run a quick local room-volume check for S&P PCD80XHP by entering square footage and ceiling height to spot under-vented steam risks early.
When does S&P PCD80XHP fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering S&P PCD80XHP.
Limitations & Who Should Skip
- Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 84 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about S&P PCD80XHP?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to S&P PCD80XHP.
Does running S&P PCD80XHP continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of S&P PCD80XHP draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can S&P PCD80XHP pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCD80XHP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P PCD80XHP?
S&P PCD80XHP features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P PCD80XHP's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCD80XHP's safe coverage footprint from 50 sq ft to 44 sq ft.
Is S&P PCD80XHP code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), S&P PCD80XHP clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than S&P PCD80XHP?
Do not force S&P PCD80XHP into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does S&P PCD80XHP retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, S&P PCD80XHP produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will S&P PCD80XHP disturb adjacent bedrooms during night use?
Acoustic measurement places S&P PCD80XHP at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)