Skip to main content
Grant Estimator

Cyclone CTLD100 Exhaust Fan Specifications

ENERGY STAR PD #2409643 · Bathroom/Utility Room · Qualified 2023-02-03
Verified Specification Summary

Rated for 100 CFM open-air (84.7 CFM at 0.25 in. w.g.), Cyclone CTLD100 omits a published 0.1-inch sone rating and delivers 13.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 84 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CTLD100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 84.7 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
13.3 CFM/W (#48/1,145)
Static Retention
84.7% @ 0.25"
Motor Draw
7.5 W (2.7 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Cyclone CTLD100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Cyclone CTLD100 (EPA filing PD #2409643) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.7 CFM at 0.25 in. w.g. (84.7% retention, 3.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Cyclone's 17-unit lineup, CTLD100 (series: CTLD) carries PD #2409643 dating to 2023-02-03. Lighting kit: No. At 13.3 CFM/W (#48 of 1,145, top 4.2% of 1,145 rated models, more efficient than 95.8% of rated models, 8.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.5 watts, about 2.7 kWh/yr (~$0.43/yr at $0.16/kWh) for 1 hr/day shower timers or 65.7 kWh/yr (~$10.51/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

How do flex elbows choke Cyclone CTLD100 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Cyclone CTLD100 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Cyclone CTLD100 meet residential exhaust fan code specs?

Inspect Cyclone CTLD100 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Cyclone (17 models) ENERGY STAR Certified Partner
Model Number & Series CTLD100 / CTLD PD ID 2409643 (Qualified 2023-02-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (84.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Cyclone CTLD100 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Cyclone CTLD100 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Cyclone CTLD100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 84 sq ft1 CFM/sq ft @ 84.7 CFM
Tall Bath (9-ft Ceiling)Up to 75 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 34 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.7 kWh/yr (~$0.43/yr)7.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.265.7 kWh/yr (~$10.51/yr)7.5 W x 8,760 hrs / 1,000

Which competing models share Cyclone CTLD100 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Revent RVS8090100 100 / 108.5 CFM Unpublished 12.7 CFM/W 4 in. diameter
Utilitech UTS8090100 100 / 108.5 CFM Unpublished 12.7 CFM/W 4 in. diameter

How much airflow margin does Cyclone CTLD100 give your bath?

Run a quick local room-volume check for Cyclone CTLD100 by entering square footage and ceiling height to spot under-vented steam risks early.

When does Cyclone CTLD100 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Cyclone CTLD100.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 84 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Cyclone CTLD100?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Cyclone CTLD100.

Will Cyclone CTLD100 disturb adjacent bedrooms during night use?

Acoustic measurement places Cyclone CTLD100 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Cyclone CTLD100 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Cyclone CTLD100 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Cyclone CTLD100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CTLD100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Cyclone CTLD100?

Cyclone CTLD100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Cyclone CTLD100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CTLD100's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Cyclone CTLD100 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Cyclone CTLD100 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Cyclone CTLD100?

Do not force Cyclone CTLD100 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Cyclone CTLD100 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Cyclone CTLD100 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories