Skip to main content
Grant Estimator

Revent RVL8090100 Exhaust Fan Specifications

ENERGY STAR PD #4610275 · Bathroom/Utility Room · Qualified 2026-04-22
Verified Specification Summary

Rated for 100 CFM open-air (109.2 CFM at 0.25 in. w.g.), Revent RVL8090100 omits a published 0.1-inch sone rating and delivers 12.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 109 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL8090100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 109.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
12.5 CFM/W (#70/1,145)
Static Retention
109.2% @ 0.25"
Motor Draw
8.0 W (2.9 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVL8090100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent RVL8090100 (EPA filing PD #4610275) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 109.2 CFM out of 100 CFM (109.2% retention, 21.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Revent's 40-unit lineup, RVL8090100 (series: ReVent) carries PD #4610275 dating to 2026-04-22. Lighting kit: Yes. At 12.5 CFM/W (#70 of 1,145, top 6.3% of 1,145 rated models, more efficient than 93.7% of rated models, 7.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.0 watts, about 2.9 kWh/yr (~$0.46/yr at $0.16/kWh) for 1 hr/day shower timers or 70.1 kWh/yr (~$11.22/yr) continuously. Closest competing matches include DewStop - Breeze Easy BEL110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

How do flex elbows choke Revent RVL8090100 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Revent RVL8090100 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Revent RVL8090100 meet residential exhaust fan code specs?

Inspect Revent RVL8090100 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVL8090100 / ReVent PD ID 4610275 (Qualified 2026-04-22)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (109.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Revent RVL8090100 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Revent RVL8090100 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Revent RVL8090100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 109 sq ft1 CFM/sq ft @ 109.2 CFM
Tall Bath (9-ft Ceiling)Up to 97 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 59 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.9 kWh/yr (~$0.46/yr)8.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.270.1 kWh/yr (~$11.22/yr)8.0 W x 8,760 hrs / 1,000

Which competing models share Revent RVL8090100 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter

How much airflow margin does Revent RVL8090100 give your bath?

Run a quick local room-volume check for Revent RVL8090100 by entering square footage and ceiling height to spot under-vented steam risks early.

When does Revent RVL8090100 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Revent RVL8090100.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 59 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 109 sq ft with 8-ft ceilings (97 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Revent RVL8090100?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Revent RVL8090100.

Which bathroom layouts should pick a larger blower than Revent RVL8090100?

Do not force Revent RVL8090100 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Revent RVL8090100 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Revent RVL8090100 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Revent RVL8090100 disturb adjacent bedrooms during night use?

Acoustic measurement places Revent RVL8090100 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Revent RVL8090100 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Revent RVL8090100 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Revent RVL8090100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL8090100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVL8090100?

Revent RVL8090100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVL8090100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL8090100's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Revent RVL8090100 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Revent RVL8090100 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories