Certified by EPA ENERGY STAR, Utilitech UTL8090100 delivers 100 CFM free-air (109.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 12.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 109 sq ft (8-ft height) or 97 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech UTL8090100 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 109.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 12.5 CFM/W (#70/1,145)
- Static Retention
- 109.2% @ 0.25"
- Motor Draw
- 8.0 W (2.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Utilitech UTL8090100 vs. 1,145-Model ENERGY STAR Benchmarks show?
Utilitech UTL8090100 (EPA filing PD #4668394) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 109.2 CFM out of 100 CFM (109.2% retention, 21.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places UTL8090100 (series: Utilitech) (PD #4668394) among 22 Utilitech entries qualified through 2026-07-08. Lighting kit: Yes. At 12.5 CFM/W (#70 of 1,145, top 6.3% of 1,145 rated models, more efficient than 93.7% of rated models, 7.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.0 watts, about 2.9 kWh/yr (~$0.46/yr at $0.16/kWh) for 1 hr/day shower timers or 70.1 kWh/yr (~$11.22/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).
Why does rigid 4 in. diameter ducting protect Utilitech UTL8090100 airflow?
Connecting Utilitech UTL8090100 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Utilitech UTL8090100 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Utilitech UTL8090100 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | UTL8090100 / Utilitech | PD ID 4668394 (Qualified 2026-07-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (109.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Utilitech UTL8090100?
Calculated coverage metrics translate Utilitech UTL8090100 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 109 sq ft | 1 CFM/sq ft @ 109.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 97 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 59 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.9 kWh/yr (~$0.46/yr) | 8.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 70.1 kWh/yr (~$11.22/yr) | 8.0 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Utilitech UTL8090100?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVL8090100 | 100 / 109.2 CFM | Unpublished | 12.5 CFM/W | 4 in. diameter |
| Revent RVS8090100 | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
Does Utilitech UTL8090100 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Utilitech UTL8090100 percentage capacity without sending data.
Where should contractors skip Utilitech UTL8090100 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Utilitech UTL8090100 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 59 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 109.2 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Utilitech UTL8090100?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Utilitech UTL8090100.
Will long attic ducting choke Utilitech UTL8090100 capacity?
Because static drag at 0.25 in. w.g. lowers Utilitech UTL8090100 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Utilitech UTL8090100 compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Utilitech UTL8090100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Utilitech UTL8090100 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Utilitech UTL8090100 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Utilitech UTL8090100 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech UTL8090100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech UTL8090100?
Utilitech UTL8090100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech UTL8090100's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech UTL8090100's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Utilitech UTL8090100 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Utilitech UTL8090100 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Utilitech UTL8090100?
Rule out Utilitech UTL8090100 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)