S&P TD-100X1 Exhaust Fan Specifications

ENERGY STAR PD #2343143 · In-line (single-port) · Qualified 2018-05-11
Verified Specification Summary

Rated for 100 CFM open-air (unpublished 0.25 in. w.g. output), S&P TD-100X1 omits a published 0.1-inch sone rating and delivers 4.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 100 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P TD-100X1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
0.1" test only
Motor Draw
24.4 W (8.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P TD-100X1 vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P TD-100X1 (EPA filing PD #2343143) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

S&P maintains 29 active ENERGY STAR blowers; TD-100X1 (series: TD-Mixvent) (PD #2343143) gained qualification on 2018-05-11. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Anzzi EF-AZ106MB (100.0 CFM) and Anzzi EF-AZ106WH (100.0 CFM).

How do flex elbows choke S&P TD-100X1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps S&P TD-100X1 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does S&P TD-100X1 meet residential exhaust fan code specs?

Inspect S&P TD-100X1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series TD-100X1 / TD-Mixvent PD ID 2343143 (Qualified 2018-05-11)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (100 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match S&P TD-100X1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect S&P TD-100X1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for S&P TD-100X1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 100 sq ft1 CFM/sq ft @ 100 CFM
Tall Bath (9-ft Ceiling)Up to 88 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 50 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.9 kWh/yr (~$1.42/yr)24.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2213.7 kWh/yr (~$34.19/yr)24.4 W x 8,760 hrs / 1,000

Which competing models share S&P TD-100X1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Anzzi EF-AZ106MB 100 / 92.8 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Anzzi EF-AZ106WH 100 / 92.8 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Fantech SMPL100 (484302) 100 / 91.2 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Fantech SMPL100L (484303) 100 / 91.2 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
ACIQ AES100 100 / 90.2 CFM 1.5 sones 4.2 CFM/W 4 in. diameter

How much airflow margin does S&P TD-100X1 give your bath?

Run a quick local room-volume check for S&P TD-100X1 by entering square footage and ceiling height to spot under-vented steam risks early.

Does S&P TD-100X1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying S&P TD-100X1 for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 100 sq ft with 8-ft ceilings (88 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about S&P TD-100X1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to S&P TD-100X1.

What acoustic sone tier does S&P TD-100X1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., S&P TD-100X1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does S&P TD-100X1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, S&P TD-100X1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can S&P TD-100X1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P TD-100X1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P TD-100X1?

S&P TD-100X1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P TD-100X1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P TD-100X1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does S&P TD-100X1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), S&P TD-100X1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install S&P TD-100X1 in a bathroom remodel?

Avoid specifying S&P TD-100X1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut S&P TD-100X1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, S&P TD-100X1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)