Certified by EPA ENERGY STAR, Venco SP-LP0810W delivers 100 CFM free-air (105.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 105 sq ft (8-ft height) or 93 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco SP-LP0810W Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 105.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.0 CFM/W (#186/1,145)
- Static Retention
- 105.5% @ 0.25"
- Motor Draw
- 10.0 W (3.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Venco SP-LP0810W vs. 1,145-Model ENERGY STAR Benchmarks show?
Venco SP-LP0810W (EPA filing PD #3629308) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 105.5 CFM out of 100 CFM (105.5% retention, 17.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Venco SP-LP0810W (series: Model SP Ceiling Fan, Direct Drive) under PD #3629308 (15 models registered, 2024-09-13). Lighting kit: No. At 10.0 CFM/W (#186 of 1,145, top 16.4% of 1,145 rated models, more efficient than 83.6% of rated models, 5.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
Why does rigid 4 in. diameter ducting protect Venco SP-LP0810W airflow?
Connecting Venco SP-LP0810W through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Venco SP-LP0810W performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Venco SP-LP0810W lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Venco (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-LP0810W / Model SP Ceiling Fan, Direct Drive | PD ID 3629308 (Qualified 2024-09-13) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (105.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Venco SP-LP0810W?
Calculated coverage metrics translate Venco SP-LP0810W airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 105 sq ft | 1 CFM/sq ft @ 105.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 93 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 55 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.6 kWh/yr (~$0.58/yr) | 10.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 87.6 kWh/yr (~$14.02/yr) | 10.0 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Venco SP-LP0810W?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Does Venco SP-LP0810W match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Venco SP-LP0810W percentage capacity without sending data.
What plumbing or duct constraints rule out Venco SP-LP0810W?
Compare where Venco SP-LP0810W excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 55 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 105.5 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Venco SP-LP0810W?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Venco SP-LP0810W.
Is Venco SP-LP0810W quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Venco SP-LP0810W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Venco SP-LP0810W energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Venco SP-LP0810W pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco SP-LP0810W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Venco SP-LP0810W?
Venco SP-LP0810W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Venco SP-LP0810W's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco SP-LP0810W's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Venco SP-LP0810W serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Venco SP-LP0810W supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Venco SP-LP0810W for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Venco SP-LP0810W lacks adequate reserve.
How does Venco SP-LP0810W handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Venco SP-LP0810W yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)