Venco SP-LP0810W Exhaust Fan Specifications

ENERGY STAR PD #3629308 · Bathroom/Utility Room · Qualified 2024-09-13
Verified Specification Summary

Certified by EPA ENERGY STAR, Venco SP-LP0810W delivers 100 CFM free-air (105.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 105 sq ft (8-ft height) or 93 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco SP-LP0810W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 105.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
10.0 CFM/W (#186/1,145)
Static Retention
105.5% @ 0.25"
Motor Draw
10.0 W (3.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Venco SP-LP0810W vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco SP-LP0810W (EPA filing PD #3629308) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 105.5 CFM out of 100 CFM (105.5% retention, 17.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Venco SP-LP0810W (series: Model SP Ceiling Fan, Direct Drive) under PD #3629308 (15 models registered, 2024-09-13). Lighting kit: No. At 10.0 CFM/W (#186 of 1,145, top 16.4% of 1,145 rated models, more efficient than 83.6% of rated models, 5.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

Why does rigid 4 in. diameter ducting protect Venco SP-LP0810W airflow?

Connecting Venco SP-LP0810W through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Venco SP-LP0810W performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Venco SP-LP0810W lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Venco (15 models) ENERGY STAR Certified Partner
Model Number & Series SP-LP0810W / Model SP Ceiling Fan, Direct Drive PD ID 3629308 (Qualified 2024-09-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (105.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Venco SP-LP0810W?

Calculated coverage metrics translate Venco SP-LP0810W airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Venco SP-LP0810W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 105 sq ft1 CFM/sq ft @ 105.5 CFM
Tall Bath (9-ft Ceiling)Up to 93 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 55 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.6 kWh/yr (~$0.58/yr)10.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.287.6 kWh/yr (~$14.02/yr)10.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Venco SP-LP0810W?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Venco SP-LP0810W match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Venco SP-LP0810W percentage capacity without sending data.

What plumbing or duct constraints rule out Venco SP-LP0810W?

Compare where Venco SP-LP0810W excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 55 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 105.5 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Venco SP-LP0810W?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Venco SP-LP0810W.

Is Venco SP-LP0810W quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Venco SP-LP0810W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Venco SP-LP0810W energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Venco SP-LP0810W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco SP-LP0810W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Venco SP-LP0810W?

Venco SP-LP0810W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Venco SP-LP0810W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco SP-LP0810W's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Venco SP-LP0810W serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Venco SP-LP0810W supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Venco SP-LP0810W for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Venco SP-LP0810W lacks adequate reserve.

How does Venco SP-LP0810W handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Venco SP-LP0810W yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories