Skip to main content
Grant Estimator

Venco VQ-LP0810W Exhaust Fan Specifications

ENERGY STAR PD #4015821 · Bathroom/Utility Room · Qualified 2025-03-07
Verified Specification Summary

The Venco VQ-LP0810W (Model SP Ceiling Fan, Direct Drive) moves 100 CFM at 0.1 in. w.g. (105.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 10.0 CFM/W efficacy, sizing bathrooms up to 105 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco VQ-LP0810W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 105.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
10.0 CFM/W (#186/1,145)
Static Retention
105.5% @ 0.25"
Motor Draw
10.0 W (3.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Venco VQ-LP0810W vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco VQ-LP0810W (EPA filing PD #4015821) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 105.5 CFM out of 100 CFM (105.5% retention, 17.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Venco maintains 15 active ENERGY STAR blowers; VQ-LP0810W (series: Model SP Ceiling Fan, Direct Drive) (PD #4015821) gained qualification on 2025-03-07. Lighting kit: No. At 10.0 CFM/W (#186 of 1,145, top 16.4% of 1,145 rated models, more efficient than 83.6% of rated models, 5.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

How does duct geometry alter Venco VQ-LP0810W static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Venco VQ-LP0810W?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Venco VQ-LP0810W alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Venco (15 models) ENERGY STAR Certified Partner
Model Number & Series VQ-LP0810W / Model SP Ceiling Fan, Direct Drive PD ID 4015821 (Qualified 2025-03-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (105.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Venco VQ-LP0810W ventilate safely?

Sizing outputs below convert Venco VQ-LP0810W tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Venco VQ-LP0810W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 105 sq ft1 CFM/sq ft @ 105.5 CFM
Tall Bath (9-ft Ceiling)Up to 93 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 55 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.6 kWh/yr (~$0.58/yr)10.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.287.6 kWh/yr (~$14.02/yr)10.0 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Venco VQ-LP0810W closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Will Venco VQ-LP0810W clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Venco VQ-LP0810W satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Venco VQ-LP0810W fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Venco VQ-LP0810W.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 55 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 105 sq ft with 8-ft ceilings (93 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Venco VQ-LP0810W?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Venco VQ-LP0810W.

Will Venco VQ-LP0810W disturb adjacent bedrooms during night use?

Acoustic measurement places Venco VQ-LP0810W at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Venco VQ-LP0810W continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Venco VQ-LP0810W draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Venco VQ-LP0810W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco VQ-LP0810W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Venco VQ-LP0810W?

Venco VQ-LP0810W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Venco VQ-LP0810W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco VQ-LP0810W's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Venco VQ-LP0810W code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Venco VQ-LP0810W clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Venco VQ-LP0810W?

Do not force Venco VQ-LP0810W into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Venco VQ-LP0810W retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Venco VQ-LP0810W produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories