Rated for 100 CFM open-air (106.9 CFM at 0.25 in. w.g.), Venco SP-LP0810WL omits a published 0.1-inch sone rating and delivers 9.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 106 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco SP-LP0810WL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 106.9 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.5 CFM/W (#234/1,145)
- Static Retention
- 106.9% @ 0.25"
- Motor Draw
- 10.5 W (3.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Venco SP-LP0810WL vs. 1,145-Model ENERGY STAR Benchmarks show?
Venco SP-LP0810WL (EPA filing PD #3629319) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.9 CFM out of 100 CFM (106.9% retention, 19.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Venco maintains 15 active ENERGY STAR blowers; SP-LP0810WL (series: Model SP Ceiling Fan, Direct Drive) (PD #3629319) gained qualification on 2024-09-13. Lighting kit: Yes. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.5 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 92.0 kWh/yr (~$14.72/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
How do flex elbows choke Venco SP-LP0810WL at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Venco SP-LP0810WL moving full rated CFM.
Does Venco SP-LP0810WL meet residential exhaust fan code specs?
Inspect Venco SP-LP0810WL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Venco (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-LP0810WL / Model SP Ceiling Fan, Direct Drive | PD ID 3629319 (Qualified 2024-09-13) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (106.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Venco SP-LP0810WL airflow output?
Annual electricity figures and room square-footage ceilings below reflect Venco SP-LP0810WL tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 95 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.0 kWh/yr (~$14.72/yr) | 10.5 W x 8,760 hrs / 1,000 |
Which competing models share Venco SP-LP0810WL airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
How much airflow margin does Venco SP-LP0810WL give your bath?
Run a quick local room-volume check for Venco SP-LP0810WL by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Venco SP-LP0810WL in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Venco SP-LP0810WL for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 56 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 106 sq ft with 8-ft ceilings (95 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Venco SP-LP0810WL?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Venco SP-LP0810WL.
How does Venco SP-LP0810WL sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Venco SP-LP0810WL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Venco SP-LP0810WL?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Venco SP-LP0810WL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco SP-LP0810WL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Venco SP-LP0810WL?
Venco SP-LP0810WL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Venco SP-LP0810WL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco SP-LP0810WL's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Venco SP-LP0810WL satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Venco SP-LP0810WL clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Venco SP-LP0810WL undersized or poorly matched for a bath renovation?
Skip Venco SP-LP0810WL if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Venco SP-LP0810WL CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Venco SP-LP0810WL registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)