Rated for 110 CFM open-air (128.3 CFM at 0.25 in. w.g.), Venco VQ-AP0511W-1 omits a published 0.1-inch sone rating and delivers 10.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 128 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco VQ-AP0511W-1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 128.3 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.4 CFM/W (#171/1,145)
- Static Retention
- 116.6% @ 0.25"
- Motor Draw
- 10.6 W (3.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Venco VQ-AP0511W-1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Venco VQ-AP0511W-1 (EPA filing PD #4015812) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 128.3 CFM out of 110 CFM (116.6% retention, 28.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Venco VQ-AP0511W-1 (series: Model SP Ceiling Fan, Direct Drive) under PD #4015812 (15 models registered, 2025-02-07). Lighting kit: No. At 10.4 CFM/W (#171 of 1,145, top 15.2% of 1,145 rated models, more efficient than 84.8% of rated models, 5.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
How do flex elbows choke Venco VQ-AP0511W-1 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Venco VQ-AP0511W-1 moving full rated CFM.
Does Venco VQ-AP0511W-1 meet residential exhaust fan code specs?
Inspect Venco VQ-AP0511W-1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Venco (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VQ-AP0511W-1 / Model SP Ceiling Fan, Direct Drive | PD ID 4015812 (Qualified 2025-02-07) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (128.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Venco VQ-AP0511W-1 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Venco VQ-AP0511W-1 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 128 sq ft | 1 CFM/sq ft @ 128.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 114 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 78 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.9 kWh/yr (~$14.86/yr) | 10.6 W x 8,760 hrs / 1,000 |
Which competing models share Venco VQ-AP0511W-1 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
How much airflow margin does Venco VQ-AP0511W-1 give your bath?
Run a quick local room-volume check for Venco VQ-AP0511W-1 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Venco VQ-AP0511W-1 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Venco VQ-AP0511W-1.
Limitations & Who Should Skip
- Steam or walk-in tub room > 78 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 128 sq ft with 8-ft ceilings (114 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Venco VQ-AP0511W-1?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Venco VQ-AP0511W-1.
Will Venco VQ-AP0511W-1 disturb adjacent bedrooms during night use?
Acoustic measurement places Venco VQ-AP0511W-1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Venco VQ-AP0511W-1 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Venco VQ-AP0511W-1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Venco VQ-AP0511W-1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco VQ-AP0511W-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Venco VQ-AP0511W-1?
Venco VQ-AP0511W-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Venco VQ-AP0511W-1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco VQ-AP0511W-1's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Venco VQ-AP0511W-1 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Venco VQ-AP0511W-1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Venco VQ-AP0511W-1?
Do not force Venco VQ-AP0511W-1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Venco VQ-AP0511W-1 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Venco VQ-AP0511W-1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)