Skip to main content
Grant Estimator

Venco VQ-AP0511W Exhaust Fan Specifications

ENERGY STAR PD #4015808 · Bathroom/Utility Room · Qualified 2024-12-13
Verified Specification Summary

Rated for 110 CFM open-air (128.3 CFM at 0.25 in. w.g.), Venco VQ-AP0511W omits a published 0.1-inch sone rating and delivers 10.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 128 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco VQ-AP0511W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 128.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
10.4 CFM/W (#171/1,145)
Static Retention
116.6% @ 0.25"
Motor Draw
10.6 W (3.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Venco VQ-AP0511W vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco VQ-AP0511W (EPA filing PD #4015808) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 128.3 CFM out of 110 CFM (116.6% retention, 28.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Venco VQ-AP0511W (series: Model SP Ceiling Fan, Direct Drive) under PD #4015808 (15 models registered, 2024-12-13). Lighting kit: No. At 10.4 CFM/W (#171 of 1,145, top 15.2% of 1,145 rated models, more efficient than 84.8% of rated models, 5.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

How do flex elbows choke Venco VQ-AP0511W at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Venco VQ-AP0511W moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Venco VQ-AP0511W meet residential exhaust fan code specs?

Inspect Venco VQ-AP0511W mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Venco (15 models) ENERGY STAR Certified Partner
Model Number & Series VQ-AP0511W / Model SP Ceiling Fan, Direct Drive PD ID 4015808 (Qualified 2024-12-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (128.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Venco VQ-AP0511W airflow output?

Annual electricity figures and room square-footage ceilings below reflect Venco VQ-AP0511W tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Venco VQ-AP0511W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 128 sq ft1 CFM/sq ft @ 128.3 CFM
Tall Bath (9-ft Ceiling)Up to 114 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 78 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.292.9 kWh/yr (~$14.86/yr)10.6 W x 8,760 hrs / 1,000

Which competing models share Venco VQ-AP0511W airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter

How much airflow margin does Venco VQ-AP0511W give your bath?

Run a quick local room-volume check for Venco VQ-AP0511W by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Venco VQ-AP0511W on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Venco VQ-AP0511W carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 78 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 128 sq ft with 8-ft ceilings (114 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Venco VQ-AP0511W?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Venco VQ-AP0511W.

Will long attic ducting choke Venco VQ-AP0511W capacity?

Because static drag at 0.25 in. w.g. lowers Venco VQ-AP0511W from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Venco VQ-AP0511W compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Venco VQ-AP0511W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Venco VQ-AP0511W consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Venco VQ-AP0511W draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Venco VQ-AP0511W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco VQ-AP0511W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Venco VQ-AP0511W?

Venco VQ-AP0511W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Venco VQ-AP0511W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco VQ-AP0511W's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Venco VQ-AP0511W score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Venco VQ-AP0511W delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Venco VQ-AP0511W?

Rule out Venco VQ-AP0511W when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories