Skip to main content
Grant Estimator

Venco VQ-AP0511WL-1 Exhaust Fan Specifications

ENERGY STAR PD #4667657 · Bathroom/Utility Room · Qualified 2026-07-08
Verified Specification Summary

Rated for 110 CFM open-air (123.9 CFM at 0.25 in. w.g.), Venco VQ-AP0511WL-1 omits a published 0.1-inch sone rating and delivers 8.7 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 123 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco VQ-AP0511WL-1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 123.9 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.7 CFM/W (#306/1,145)
Static Retention
112.6% @ 0.25"
Motor Draw
12.6 W (4.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Venco VQ-AP0511WL-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco VQ-AP0511WL-1 (EPA filing PD #4667657) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 123.9 CFM out of 110 CFM (112.6% retention, 24.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places VQ-AP0511WL-1 (series: Model SP Ceiling Fan, Direct Drive) (PD #4667657) among 15 Venco entries qualified through 2026-07-08. Lighting kit: Yes. At 8.7 CFM/W (#306 of 1,145, top 27.6% of 1,145 rated models, more efficient than 72.4% of rated models, 4.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.6 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 110.4 kWh/yr (~$17.66/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

How do flex elbows choke Venco VQ-AP0511WL-1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Venco VQ-AP0511WL-1 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Venco VQ-AP0511WL-1 meet residential exhaust fan code specs?

Inspect Venco VQ-AP0511WL-1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Venco (15 models) ENERGY STAR Certified Partner
Model Number & Series VQ-AP0511WL-1 / Model SP Ceiling Fan, Direct Drive PD ID 4667657 (Qualified 2026-07-08)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (123.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Venco VQ-AP0511WL-1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Venco VQ-AP0511WL-1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Venco VQ-AP0511WL-1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 123 sq ft1 CFM/sq ft @ 123.9 CFM
Tall Bath (9-ft Ceiling)Up to 110 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 73 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.6 kWh/yr (~$0.74/yr)12.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2110.4 kWh/yr (~$17.66/yr)12.6 W x 8,760 hrs / 1,000

Which competing models share Venco VQ-AP0511WL-1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does Venco VQ-AP0511WL-1 give your bath?

Run a quick local room-volume check for Venco VQ-AP0511WL-1 by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Venco VQ-AP0511WL-1?

Match Venco VQ-AP0511WL-1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 73 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 123 sq ft with 8-ft ceilings (110 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Venco VQ-AP0511WL-1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Venco VQ-AP0511WL-1.

Where does Venco VQ-AP0511WL-1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Venco VQ-AP0511WL-1.

What happens to Venco VQ-AP0511WL-1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Venco VQ-AP0511WL-1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Venco VQ-AP0511WL-1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Venco VQ-AP0511WL-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Venco VQ-AP0511WL-1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Venco VQ-AP0511WL-1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Venco VQ-AP0511WL-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco VQ-AP0511WL-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Venco VQ-AP0511WL-1?

Venco VQ-AP0511WL-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Venco VQ-AP0511WL-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco VQ-AP0511WL-1's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Venco VQ-AP0511WL-1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Venco VQ-AP0511WL-1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories