The Broan AE80BL = A000HLKT with AE80BLF1 (INVENT) moves 80 CFM at 0.1 in. w.g. (60 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones), and delivers 3.0 CFM/W efficacy, sizing bathrooms up to 60 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80BL = A000HLKT with AE80BLF1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 60 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 75.0% @ 0.25"
- Motor Draw
- 26.7 W (9.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE80BL = A000HLKT with AE80BLF1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4698074 verifies AE80BL = A000HLKT with AE80BLF1 (series: INVENT) under Broan (207 listed models, qualified 2026-09-02). Lighting kit: Yes. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.7 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 233.9 kWh/yr (~$37.42/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).
Where does Broan AE80BL = A000HLKT with AE80BLF1 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.7 sones against all 1,145 EPA listings.
How does duct geometry alter Broan AE80BL = A000HLKT with AE80BLF1 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan AE80BL = A000HLKT with AE80BLF1?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AE80BL = A000HLKT with AE80BLF1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80BL = A000HLKT with AE80BLF1 / INVENT | PD ID 4698074 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Broan AE80BL = A000HLKT with AE80BLF1 ventilate safely?
Sizing outputs below convert Broan AE80BL = A000HLKT with AE80BLF1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 233.9 kWh/yr (~$37.42/yr) | 26.7 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan AE80BL = A000HLKT with AE80BLF1 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Milano TY-80-E | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Milano TY-80-EH | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Hunter 90704 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Hunter 90705 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Nutone AER80LWH | 80 / 59.4 CFM | 0.8 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
Will Broan AE80BL = A000HLKT with AE80BLF1 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan AE80BL = A000HLKT with AE80BLF1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Broan AE80BL = A000HLKT with AE80BLF1 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan AE80BL = A000HLKT with AE80BLF1.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Broan AE80BL = A000HLKT with AE80BLF1?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AE80BL = A000HLKT with AE80BLF1.
How much airflow does Broan AE80BL = A000HLKT with AE80BLF1 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan AE80BL = A000HLKT with AE80BLF1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Broan AE80BL = A000HLKT with AE80BLF1 disturb adjacent bedrooms during night use?
Acoustic measurement places Broan AE80BL = A000HLKT with AE80BLF1 at 0.7 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Broan AE80BL = A000HLKT with AE80BLF1 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan AE80BL = A000HLKT with AE80BLF1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan AE80BL = A000HLKT with AE80BLF1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80BL = A000HLKT with AE80BLF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80BL = A000HLKT with AE80BLF1?
Broan AE80BL = A000HLKT with AE80BLF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80BL = A000HLKT with AE80BLF1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80BL = A000HLKT with AE80BLF1's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan AE80BL = A000HLKT with AE80BLF1 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan AE80BL = A000HLKT with AE80BLF1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan AE80BL = A000HLKT with AE80BLF1?
Do not force Broan AE80BL = A000HLKT with AE80BLF1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)