Homeowners specifying Broan AE80BL=H000HLKT with AE80BLF1 gain 80 CFM at 0.1 in. w.g. (60 CFM at 0.25 in. w.g.) where it registers #135 of 607 in quietness (0.7 sones) and delivers 3.0 CFM/W efficacy, venting bathrooms up to 60 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80BL=H000HLKT with AE80BLF1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 60 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 75.0% @ 0.25"
- Motor Draw
- 26.7 W (9.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE80BL=H000HLKT with AE80BLF1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Broan's 207-unit lineup, AE80BL=H000HLKT with AE80BLF1 (series: FLEX) carries PD #2524258 dating to 2023-06-23. Lighting kit: Yes. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.7 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 233.9 kWh/yr (~$37.42/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).
What acoustic percentile does Broan AE80BL=H000HLKT with AE80BLF1 occupy among 1,145 bath blowers?
Inspect how Broan AE80BL=H000HLKT with AE80BLF1 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Broan AE80BL=H000HLKT with AE80BLF1 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan AE80BL=H000HLKT with AE80BLF1 housings.
Where do Broan AE80BL=H000HLKT with AE80BLF1 acoustic and static metrics stand?
Compare Broan AE80BL=H000HLKT with AE80BLF1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80BL=H000HLKT with AE80BLF1 / FLEX | PD ID 2524258 (Qualified 2023-06-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Broan AE80BL=H000HLKT with AE80BLF1 handle taller ceilings or walk-in tub steam?
Evaluate how Broan AE80BL=H000HLKT with AE80BLF1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 233.9 kWh/yr (~$37.42/yr) | 26.7 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Broan AE80BL=H000HLKT with AE80BLF1?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Milano TY-80-E | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Milano TY-80-EH | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Hunter 90704 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Hunter 90705 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Nutone AER80LWH | 80 / 59.4 CFM | 0.8 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
Is Broan AE80BL=H000HLKT with AE80BLF1 sized right for your shower or tub room?
Check whether Broan AE80BL=H000HLKT with AE80BLF1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
What plumbing or duct constraints rule out Broan AE80BL=H000HLKT with AE80BLF1?
Compare where Broan AE80BL=H000HLKT with AE80BLF1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 60 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Broan AE80BL=H000HLKT with AE80BLF1?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AE80BL=H000HLKT with AE80BLF1.
Why might a contractor swap Broan AE80BL=H000HLKT with AE80BLF1 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE80BL=H000HLKT with AE80BLF1 lacks adequate reserve.
How does Broan AE80BL=H000HLKT with AE80BLF1 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE80BL=H000HLKT with AE80BLF1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Broan AE80BL=H000HLKT with AE80BLF1 quiet enough for a primary bedroom bathroom?
At 0.7 sones, Broan AE80BL=H000HLKT with AE80BLF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan AE80BL=H000HLKT with AE80BLF1 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan AE80BL=H000HLKT with AE80BLF1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80BL=H000HLKT with AE80BLF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80BL=H000HLKT with AE80BLF1?
Broan AE80BL=H000HLKT with AE80BLF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80BL=H000HLKT with AE80BLF1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80BL=H000HLKT with AE80BLF1's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Broan AE80BL=H000HLKT with AE80BLF1 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan AE80BL=H000HLKT with AE80BLF1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)