Rated for 80 CFM open-air (60 CFM at 0.25 in. w.g.), Broan AE80BL=H000HLNF with AE80BLF1 registers #135 of 607 in quietness (0.7 sones) and delivers 3.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80BL=H000HLNF with AE80BLF1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 60 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 75.0% @ 0.25"
- Motor Draw
- 26.7 W (9.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE80BL=H000HLNF with AE80BLF1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2524259 verifies AE80BL=H000HLNF with AE80BLF1 (series: FLEX) under Broan (207 listed models, qualified 2023-06-23). Lighting kit: Yes. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.7 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 233.9 kWh/yr (~$37.42/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).
How does Broan AE80BL=H000HLNF with AE80BLF1 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan AE80BL=H000HLNF with AE80BLF1 (0.7 sones).
How do flex elbows choke Broan AE80BL=H000HLNF with AE80BLF1 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan AE80BL=H000HLNF with AE80BLF1 moving full rated CFM.
Does Broan AE80BL=H000HLNF with AE80BLF1 meet residential exhaust fan code specs?
Inspect Broan AE80BL=H000HLNF with AE80BLF1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80BL=H000HLNF with AE80BLF1 / FLEX | PD ID 2524259 (Qualified 2023-06-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Broan AE80BL=H000HLNF with AE80BLF1 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan AE80BL=H000HLNF with AE80BLF1 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 233.9 kWh/yr (~$37.42/yr) | 26.7 W x 8,760 hrs / 1,000 |
Which competing models share Broan AE80BL=H000HLNF with AE80BLF1 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Milano TY-80-E | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Milano TY-80-EH | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Hunter 90704 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Hunter 90705 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Nutone AER80LWH | 80 / 59.4 CFM | 0.8 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
How much airflow margin does Broan AE80BL=H000HLNF with AE80BLF1 give your bath?
Run a quick local room-volume check for Broan AE80BL=H000HLNF with AE80BLF1 by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Broan AE80BL=H000HLNF with AE80BLF1?
Match Broan AE80BL=H000HLNF with AE80BLF1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Broan AE80BL=H000HLNF with AE80BLF1?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan AE80BL=H000HLNF with AE80BLF1.
What does Broan AE80BL=H000HLNF with AE80BLF1 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan AE80BL=H000HLNF with AE80BLF1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan AE80BL=H000HLNF with AE80BLF1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80BL=H000HLNF with AE80BLF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80BL=H000HLNF with AE80BLF1?
Broan AE80BL=H000HLNF with AE80BLF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80BL=H000HLNF with AE80BLF1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80BL=H000HLNF with AE80BLF1's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan AE80BL=H000HLNF with AE80BLF1 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan AE80BL=H000HLNF with AE80BLF1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan AE80BL=H000HLNF with AE80BLF1 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan AE80BL=H000HLNF with AE80BLF1.
What happens to Broan AE80BL=H000HLNF with AE80BLF1 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan AE80BL=H000HLNF with AE80BLF1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Broan AE80BL=H000HLNF with AE80BLF1 sit on acoustic comfort for senior homeowners?
Measuring 0.7 sones, Broan AE80BL=H000HLNF with AE80BLF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)