The Broan GLA3364SS (RANGE HOOD) moves 160 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 3.8 CFM/W efficacy, sizing bathrooms up to 160 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan GLA3364SS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 160 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 42.1 W (15.4 kWh/yr)
- Duct & Tier
- 3.25 x 10 in. rectangular · Standard

What does Broan GLA3364SS vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan GLA3364SS (EPA filing PD #3998909) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.
Brand catalog footprint: Broan registers 207 certified models, with SKU GLA3364SS (series: RANGE HOOD) (PD #3998909) certified since 2025-02-21. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 42.1 watts, about 15.4 kWh/yr (~$2.46/yr at $0.16/kWh) for 1 hr/day shower timers or 368.8 kWh/yr (~$59.01/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Broan ALT4306SS (160.0 CFM).
How does duct geometry alter Broan GLA3364SS static pressure?
Smooth 3.25 x 10 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan GLA3364SS?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan GLA3364SS alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | GLA3364SS / RANGE HOOD | PD ID 3998909 (Qualified 2025-02-21) |
| Duct Connection | 3.25 x 10 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (160 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Broan GLA3364SS ventilate safely?
Sizing outputs below convert Broan GLA3364SS tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 160 sq ft | 1 CFM/sq ft @ 160 CFM |
| Tall Bath (9-ft Ceiling) | Up to 142 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 110 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 15.4 kWh/yr (~$2.46/yr) | 42.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 368.8 kWh/yr (~$59.01/yr) | 42.1 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan GLA3364SS closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Best UCB3I30BLSB | 160 / N/A CFM | Unpublished | 3.2 CFM/W | 3.25 in. diameter |
Will Broan GLA3364SS clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan GLA3364SS satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Broan GLA3364SS in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan GLA3364SS for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 110 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 160 sq ft with 8-ft ceilings (142 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 3.25 x 10 in. rectangular
What key rules and numbers govern Broan GLA3364SS?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan GLA3364SS.
When is Broan GLA3364SS undersized or poorly matched for a bath renovation?
Skip Broan GLA3364SS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Broan GLA3364SS CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan GLA3364SS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3.25 x 10 in. rectangular duct runs vital.
How does Broan GLA3364SS sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Broan GLA3364SS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Broan GLA3364SS?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Broan GLA3364SS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan GLA3364SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan GLA3364SS?
Broan GLA3364SS features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan GLA3364SS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan GLA3364SS's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan GLA3364SS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan GLA3364SS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)