Skip to main content
Grant Estimator

Commercial Electric BF1115 Exhaust Fan Specifications

ENERGY STAR PD #3531187 · Bathroom/Utility Room · Qualified 2024-05-24
Verified Specification Summary

Certified by EPA ENERGY STAR, Commercial Electric BF1115 delivers 160 CFM free-air (129.4 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 129 sq ft (8-ft height) or 115 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1115 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
160 / 129.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
80.9% @ 0.25"
Motor Draw
36.4 W (13.3 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Commercial Electric BF1115 vs. 1,145-Model ENERGY STAR Benchmarks show?

Commercial Electric BF1115 (EPA filing PD #3531187) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 160 CFM open-air to 129.4 CFM at 0.25 in. w.g. (80.9% retention, 6.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places BF1115 (series: BF1115) (PD #3531187) among 15 Commercial Electric entries qualified through 2024-05-24. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 36.4 watts, about 13.3 kWh/yr (~$2.13/yr at $0.16/kWh) for 1 hr/day shower timers or 318.9 kWh/yr (~$51.02/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and Broan QT150LE (150.0 CFM).

Why does rigid 6 in. diameter ducting protect Commercial Electric BF1115 airflow?

Connecting Commercial Electric BF1115 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Commercial Electric BF1115 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Commercial Electric BF1115 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Commercial Electric (15 models) ENERGY STAR Certified Partner
Model Number & Series BF1115 / BF1115 PD ID 3531187 (Qualified 2024-05-24)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (129.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Commercial Electric BF1115?

Calculated coverage metrics translate Commercial Electric BF1115 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Commercial Electric BF1115
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 129 sq ft1 CFM/sq ft @ 129.4 CFM
Tall Bath (9-ft Ceiling)Up to 115 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 79 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)13.3 kWh/yr (~$2.13/yr)36.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2318.9 kWh/yr (~$51.02/yr)36.4 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Commercial Electric BF1115?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
S&P TD-125 160 / N/A CFM Unpublished 4.5 CFM/W 5 in. diameter

Does Commercial Electric BF1115 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Commercial Electric BF1115 percentage capacity without sending data.

Which bath layouts should avoid specifying Commercial Electric BF1115?

Match Commercial Electric BF1115 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 79 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 129.4 CFM net static output
  • Optimal use: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Commercial Electric BF1115?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Commercial Electric BF1115.

Where does Commercial Electric BF1115 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Commercial Electric BF1115.

What happens to Commercial Electric BF1115 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Commercial Electric BF1115 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Commercial Electric BF1115 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Commercial Electric BF1115 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Commercial Electric BF1115 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Commercial Electric BF1115 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Commercial Electric BF1115 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1115's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Commercial Electric BF1115?

Commercial Electric BF1115 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Commercial Electric BF1115's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1115's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Commercial Electric BF1115 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BF1115 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories